 P90 Zero Clearance Direct Vent Gas Fireplace
9
INSTALLATION
Fireplace
Stand
No hearth is
required when
the unit is raised
3" (76mm) off of
the floor surface
Flooring
HEARTH REQUIREMENTS
Floor Mounted Fireplaces
Raised Fireplaces
FACING REQUIREMENT
This fi replace requires a non-combustible material extending from the 
framing header and sides. 
The fl anges on the front face of the fi replace are for a facing thickness 
of 1" (25mm).
Facing Over 1" (25mm) Thick
If the facing material is over 1" (25mm)  thick (example: brick or river 
rock), install the facing around the perimeter of the face. You may wish 
to make a face template as shown on the diagram.
FPI offers a cover plate 
template. See next page.
NOTE: If using a brick 
hearth, the fi replace will 
need to be raised to 
accommodate the brick 
thickness. Example: If the 
brick is 2" thick, the unit 
must be raised 1".
Note: 4 8 "   ( 1 1 2 1 9 m m ) 
i s   t h e   m i n i m u m 
height for both fl ex 
termination or Rigid 
Pipe venting.
4)  Note:  The unit does not 
have to be completely 
enclosed in a chase. The 
clearance on top of the 
unit is 0" to the standoffs 
so combustible building 
materials can be laid 
directly on top of the 
standoffs. You must 
maintain  clearance from 
the vent to combustible 
m a t e r i a l s   f o r   b o t h 
rigid and fl ex, see  the 
"Clearances" section.
Yo u   m u s t   t a k e   i n t o 
account the depth of the 
floor covering (carpet, 
tile, linoleum, etc.) when 
determining the height of 
the fi replace stand.
The  HeatWave Duct Kit has different 
clearance and framing requirements, check 
the HeatWave manual for details.
Please note that all vertical measurements are taken from the base 
of the unit excluding risers or bottom stand-offs.