220Volt Circulation Pump With 220 Volt Chlorine Generator 
 
 
 
120Volt Circulation Pump With 240 Volt Chlorine Generator 
 
A 240 Volt Chlorine Generator may NOT be connected to a system with a 120 Volt circulation pump.   
 
 
 
W i r i n g   t h e   C e l l  
 
Connect the two black wires from the Control Box to the two metal studs on the sides of the Cell and tighten 
firmly with a screwdriver by hand.  To avoid damage to the screws, DO NOT use a power screwdriver.  Note 
these wires are interchangeable.  Push the plastic terminal covers up to cover the terminal connection until 
they click into place.  This will ensure a watertight connection. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
W i r i n g   t h e   F l o w   S e n s o r  
 
Find the two 18 AWG wires with the ¼” Quick connect terminals from the Cell cable and push them on their 
respective connectors on the Flow Sensor.  These wires are interchangeable.