Analog Devices ADXL345 ユーザーズマニュアル

ページ / 12
UG-015 
Evaluation Board User Guide
 
Rev. 0 | Page 10 of 12 
TEMPERATURE TAB 
08
11
9-
01
2
 
The Temperature tab is used to examine the performance of 
the ADXL345 over temperature. By plotting the acceleration vs. 
temperature while the ADXL345 is not experiencing dynamic 
acceleration, the offset temperature coefficient can be determined 
by taking the slope of the best-fit line to the acceleration vs. 
temperature data. The inertial sensor evaluation system assists 
in the accuracy of this measurement by putting the accelerometer 
on a separate satellite. Only the satellite has to be placed in an 
environmental chamber, which eliminates inaccuracies due to 
the temperature effects of voltage sources, converters, and other 
biasing circuits. 
The Temperature tab, shown in Figure 15, allows a maximum 
number of points to be set and at what rate data is acquired. The 
testing can be stopped before reaching the maximum number of 
points. The data rate for the accelerometer can also be set to ensure 
that the testing is performed under conditions most like those 
that the part would be configured for in a system. 
Figure 15. Temperature Tab 
The data in the top graph in Figure 15 is used for determining 
the offset temperature coefficient. The bottom graph displays 
the temperature over time. To save data, a measurement cannot 
be in progress. When the measurement ends or is stopped, click 
the Save Data button to save the data to a .txt file. 
After selecting the values in the Sample PointsTime Interval [s], 
and Data Rate [Hz] boxes, data acquisition begins by clicking 
the Start Meas button. When testing is in progress, the Meas. 
In Progress
 indicator lights up. To end the test before the 
maximum number of points, click the Stop Meas button.