USING THE BOARD 
GETTING STARTED 
The development board comes preprogrammed as a datalogger 
at a 100 Hz datarate. To log data, do the following:  
1.  Insert two AAA batteries into the battery holder.  
2.  Insert the MicroSD card into the slot. The card should be 
formatted with a FAT32 file system; most microSD cards 
come this way.  
3.  Push the on/off switch to the on position to power up the 
board. The red LED turns on, and the green LED blinks to 
indicate that the board is logging data.  
4.  When logging is completed, slide the on/off switch to the 
off position.  
5.  Remove the card from the slot and insert it into the card 
reader. 
6.  Insert the card reader into the USB port on your computer. 
The acceleration log file is written to the path \XL345\DB0001.txt 
on the microSD card. The data in the text file consists of a set of 
comma-separated t, x, y, and z values, where t corresponds to 
time and x, y, and z correspond to the x-, y-, and z-axis acceleration 
data for each time point. Acceleration values are logged in LSB, 
where the nominal scale factor is 3.9 mg/LSB. To convert an 
acceleration value from LSB to mg, simply multiply by 3.9 
(nominally, or measure the sensitivity of the part for a more 
accurate conversion).  
To plot the logged data using Microsoft Excel, download the 
XL345DB_DataPlotter.xls file from the 
ADXL345
 product page 
and follow the instructions described in the file. Users are 
prompted to browse to their logged data file (DBxxxx.txt), the 
data is imported and plotted in a new workbook, and users are 
then prompted to save that workbook. 
PROGRAMMING THE BOARD 
The board can be repurposed with no programming required 
using the .hex files provided on the ADXL345 product page. 
The .hex files are uploaded onto the board using the ARMWSD 
program, which can be downloaded at 
ftp://ftp.analog.com/pub/MicroConverter/ARM%20Tools/AR
MWSDv1.8.zip
.
 
Simply unzip the folder to a known location 
and open the ARMWSD.exe file to use the program. No 
installation is required. 
To reprogram the board, use the cable provided with the board and 
follow these instructions: 
1.  Download the desired .hex file from the ADXL345 product 
page to a known location, or locate it on your machine. 
2.  Open ARMWSD.  
3.  Click Configure… (see Figure 3) and select the Parts tab, 
shown in see. Make sure the ADuC7024 is selected in the 
Select Part
 pull-down list (see Figure 4). Additionally, in the 
Comms
 tab, make sure the Baudrate is set to 115200, and 
the Serial Port is set to COM1, and then click OK
4.  In the ARMWSD window, click Browse…, see encircled in 
Figure 3, and navigate to the location of the .hex file to be 
loaded onto the board. Select the file and click Open.  
0
8
6
5
8
-0
0
3
 
Figure 3. ARMWSD Window  
0
8
6
5
8
-0
0
5
 
Figure 4. ARMWSD Configure Window: Parts Tab  
5.  Connect the programming cable to the serial port on the 
PC and to the 4-pin header near the on/off switch on 
the board, matching up the corresponding pins. 
6.  In the ARMWSD window, click Start. The Status 
frame then prompts users to Press Download and 
pulse Reset on Hardware
. Follow the illustrations in 
Figure 2. 
7.  When download is complete, click the Reset button on 
the evaluation board. The ARMWSD program can now 
be closed. 
 
 
 
SOFTWARE TOOLS 
In addition to the ready-to-upload examples provided on the 
ADXL345
 product page, the development board is fully modifiable 
and reprogrammable to allow for easy prototyping and firmware 
development. Firmware is written in C, and it is compiled for