Product Information - NetLinx Modules
5
NetLinx Master Cards and Modules
Modes and front panel LED blink patterns
The following table lists the modes for the Master Cards/Modules and blink patterns for the front 
panel LEDs for each mode.
Rear panel LEDs: ICSNet/ICSHub
Rear panel LEDs: AXLink
Modes and LED Blink Patterns
LEDs and Blink Patterns
Mode
Description
STATUS
(green)
OUTPUT
(red)
INPUT
(yellow)
OK
Master is functioning properly
1 Blink
Normal
Normal
Boot
Master is rebooting.
On
On
On
Missing device(s)
Master detects one or more devices 
defined in the NetLinx program that are not 
present or connected to the bus.
2 Blinks
Normal
Normal
AXlink bus failure
Master detects a communication failure on 
the AXlink bus.
3 Blinks
Normal
Normal
Contacting DHCP server Master is contacting a DHCP server for IP 
configuration information.
On
Off
Fast Blink
Unknown DHCP server
Master could not find the DHCP server.
Fast Blink
Off
Off
Downloading program/
firmware
Downloading a program to the Master 
Card's on-board flash memory.
Fast Blink Fast Blink Fast Blink
No program running
There is no program loaded, or the pro-
gram is disabled.
On
Normal
Normal
FIG. 2  Layouts of the ICSNet, ICSHub and Ethernet LEDs
AXLink LED Blink Patterns
Blink Pattern
Description
Off
No power or the controller is not functioning properly.
1 blink per second
Normal operation. Device numbers match the programmed device numbers in 
the Axcess program.
2 blinks per second
Device numbers do not match the Axcess program, a device is not present, or 
a device is not set to the right number.
3 blinks per second
AXlink bus error. Check all AXlink bus connections.
Full on
Axcess program is not present and there is no AXlink activity.
ICSNet
OUT
ICSHub
IN
ICSHub OUT LED (yellow): 
lights to indicate data input 
activity on this port.
ICSNet LED (green): lights
to indicate data output
activity on this port.
ICSHub IN LED (yellow): 
lights to indicate data 
input activity on this port.
PW
R
GN
D
AX
M
AXP
AXlink