AMX NXC-M/ME/MPE ユーザーズマニュアル

ページ / 48
Installation and Wiring
18
NetLinx Master Cards and Modules
6.
Inside the Master Card slot on the NXF or NXI, find the 6-pin control cable connector.
7.
Plug the connector from the NXF or NXI into the 6-pin terminal on the Master Card. This 
connector is keyed to ensure correct orientation.
8.
Once the control cable is connected, gently slide the card in until you feel the rear edge of the 
card snap into place.
9.
Re-apply power and other connections as necessary.
Preparing/connecting captive wires
1.
Strip 0.25 inch of wire insulation off all wires.
2.
Insert each wire into the appropriate opening on the connector according to the wiring 
diagrams and connector types described in this section. Do not tighten the screws excessively; 
doing so may strip the threads and damage the connector.
ICSNet RJ-45 Connections/Wiring
The following table shows the pinouts, signals, and pairing information to use for ICSNet RJ-45 
connections. The ICSNet connections provide power and data to ICSNet devices. Each port 
provides up to 500 mA of current.
ICSNet RJ-45 Pinouts/Signals
Pin
Signal
Connections
Pairing
1
TX +
1 --------- 1
1 --------- 2
2
TX -
2 --------- 2
3
Mic -
3 --------- 3
3 --------- 6
4
GND
4 --------- 4
5
12 VDC
5 --------- 5
4 --------- 5
6
Mic +
6 --------- 6
7
RX +
7 --------- 7
7 --------- 8
8
RX -
8 --------- 8
RJ-45 plug
RJ-45 plug