♦  Basic Rate: The maximum rate of multicast, broadcast and control frames 
transmissions. Multicast and broadcast transmissions are not acknowledged; 
therefore there is a chance that such transmissions will not be properly 
received without the possibility of using the acknowledgement mechanism for 
retransmission. Therefore, it is recommended to use a lower rate for 
transmission of broadcast, multicast and control frames, to increase the 
probability that they will be received without errors. Enter the data rate at 
which broadcast, multicast and control frames are transmitted. The valid 
values are 1, 2, 5.5 and 11 Mbps. The default value is 2 Mbps. 
NOTE: 
The Basic Rate parameter should be changed only if you are sure that all units in the cell can handle the 
defined rate. Use this parameter with caution, as it may bring the link down. 
 
♦  Power: The transmit power level. The possible values are -4, -2, 4, 6, 12, 14, 
20, 24 dBm. 
 
NOTE: 
The Power setting should not exceed the maximum output allowed in the applicable regulatory domain 
according to Table