SPECIAL APPLICATION
400-0517-001
22
7.4 AVSNAP
AVSnap provides a complete environment for 
designing simple to sophisticated graphical user 
interfaces (GUIs). AVSnap is preinstalled on each 
CP450 making it easy to integrate into any control 
environment.
Everything needed to start is included in a sample 
application. Use the predefined procedures and 
functions to communicate with devices over 
RS-232 or LAN, or create your own custom 
functions. In addition to standard communication 
and control, the functions below  are useful for 
typical touch screen applications and can be 
assigned to buttons or placed in startup and 
shutdown routines. The samples shown here 
require an application object named “App1” to be 
part of the application.
App1.Shutdown .............. Close the application and 
turn off the computer.
App1.SleepMonitor ......... Turn off monitor power.
App1.Quit ....................... Quit
the runtime 
environment and return to 
edit mode if running an 
AMT file. If running an 
EXE file, quit  the  EXE
and close the application.
App1.Stop....................... Stop the executable 
application. 
Use with EXE files only!!!
App1.Powersave ............ Hibernate  (standby)  the 
computer per display 
property settings.
App1.RunScreensaver.... Launch the screensaver.
If no screensaver is 
installed this command 
has no effect.
TROUBLESHOOTING GUIDE
8
We have carefully tested and found no problems in 
the supplied CP450; however, we would like to 
offer suggestions for the following:
8.1  POWER IS NOT ON
Cause 1:
No AC power.
Solution:
Verify the adapter is plugged into a 
working AC outlet and that the outlet 
has power. Use only the AC adapter 
that was shipped with the unit.
Cause 2:
Adapter is not plugged into 
CP450.
Solution:
Verify the DC power plug coming 
from the AC adapter is plugged all 
the way into the CP450.
Cause 3:
The CP450 has a problem.
Solution:
If there is AC power to the adapter 
and the LED still does not turn on, 
the  CP450  or the power adapter 
may require service. Call ALTINEX 
at (714) 990-2300.
8.2  SOFTWARE/FILES ARE MISSING
Cause 1:
Changes were not committed to 
memory.
Solution:
Make changes to the CP450 then 
run the COMMIT batch file on the 
desktop before shutting down or 
restarting the CP450
Cause 2:
File/application was open when 
COMMIT was executed.
Solution:
Any files that are open for editing 
must be closed before executing the 
COMMIT batch file. For best results, 
close all applications and files before 
running the COMMIT batch file.