Agilent Technologies Printer Accessories 1670G ユーザーズマニュアル
LOAD:IASSembler
Command
:MMEMory:LOAD:IASSembler <IA_name>[,<msus>],{1|2}
[,<module>]
[,<module>]
This variation of the LOAD command allows inverse assembler files to be
loaded into a module that performs state analysis. The
loaded into a module that performs state analysis. The
<IA_name>
parameter specifies the inverse assembler filename from the desired
<msus>
. The parameter after the optional
<msus>
specifies which machine
to load the inverse assembler into.
The optional
<module>
parameter is used to specify which slot the state
analyzer in. 1 refers to the logic analyzer. If this parameter is not specified,
the state analyzer will be selected.
the state analyzer will be selected.
<IA_name>
A string of up to 10 alphanumeric characters for LIF in the following form:
NNNNNNNNNN
or
A string of up to 12 alphanumeric characters for DOS in the following form:
A string of up to 12 alphanumeric characters for DOS in the following form:
NNNNNNNN.NNN
<msus>
Mass Storage Unit specifier.
INTernal0
for the hard disk drive and
INTernal1
for the flexible disk drive.
<module>
An integer, always 1
Example
OUTPUT XXX;":MMEMORY:LOAD:IASSEMBLER ’I68020 IP’,1"
OUTPUT XXX;":MMEM:LOAD:IASS ’I68020 IP’,INTERNAL0,1,2"