TCONtrol (Timer Control)
Command
:MACHine{1|2}:TTRigger:TCONtrol<N> <timer_num>,
{OFF|STARt|PAUSe|CONTinue}
The TCONtrol command turns off, starts, pauses, or continues the timer for
the specified level.  The time value of the timer is defined by the TIMER
command.
<N>
integer from 1 to the number of existing sequence levels (maximum 10)
<timer_num>
{1|2}
Example
OUTPUT XXX;":MACHINE2:TTRIGGER:TCONTROL6 1, PAUSE"
Query
:MACHine{1|2}:TTRigger:TCONTROL<N>? <timer_num>
The TCONtrol query returns the current TCONtrol setting of the specified
level.
Returned Format
[:MACHine{1|2}:TTRigger:TCONTROL<N> <timer_num>]
{OFF|STARt|PAUSe|CONTinue}<NL>
Example
OUTPUT XXX;":MACHINE2:TTRIGGER:TCONTROL6? 1"
TTRigger (TTRace) Subsystem
TCONtrol (Timer Control)