Command 
:MACHine{1|2}:TWAVeform:MLENgth <memory_length>
The MLENgth command specifies the analyzer memory depth.  Valid memory
depths range from 4096 states (or samples) through the maximum system
memory depth minus 8192 states.  Memory depth is affected by acquisition
mode.  If the <memory_depth> value sent with the command is not a legal
value, the closest legal setting will be used.
<memory_length>
{4096 | 8192 | 16384 | 32768 | 65536 | 131072 |
262144 | 524288 | 1032192}
Example
OUTPUT XXX;":MACHINE1:TWAVEFORM:MLENGTH 262144"
Query
:MACHine{1|2}:TWAVeform:MLENgth?
The MLENgth query returns the current analyzer memory depth selection.
Returned Format
[:MACHine{1|2}:TWAVeform:MLENgth] <memory_length><NL>
Example
OUTPUT XXX;":MACHINE1:TWAVEFORM:MLENGTH?"