Agilent Technologies Printer Accessories 1670G ユーザーズマニュアル
DATA
Query
:MACHine{1|2}:TLISt:DATA?
<line_number>,<label_name>
<line_number>,<label_name>
The DATA query returns the value at a specified line number for a given
label. The format will be the same as the one shown in the Listing display.
label. The format will be the same as the one shown in the Listing display.
Returned Format
[:MACHine{1|2}:TLISt:DATA] <line_number>,<label_name>,
<pattern_string><NL>
<line_number>
integer from -1032192 to +1032192
<label_name>
string of up to 6 alphanumeric characters
<pattern_
string>
"{#B{0|1|X} . . . |
#Q{0|1|2|3|4|5|6|7|X} . . . |
#H{0|1|2|3|4|5|6|7|8|9|A|B|C|D|E|F|X} . . . |
{0|1|2|3|4|5|6|7|8|9} . . . }"
Example
OUTPUT XXX;":MACHINE1:TLIST:DATA? 512, ’RAS’"
LINE
Command
:MACHine{1|2}:TLISt:LINE <line_num_mid_screen>
The LINE command moves the timing analyzer listing vertically. The
command specifies the state line number relative to the trigger that the
analyzer highlights at the center of the screen.
command specifies the state line number relative to the trigger that the
analyzer highlights at the center of the screen.
<line_num_mid_
screen>
integer from -1032192 to +1032192
Example
OUTPUT XXX;":MACHINE1:TLIST:LINE 0"
TLISt Subsystem
DATA