AVOLt
Command
:MARKer:AVOLt CHANnel<N>,<level>
The AVOLt command  moves the A marker to the specified voltage on the
indicated channel.
<N>
{1|2}
<level>
the desired marker voltage level, 
 ±
(2 
×
 maximum offset)
Example
OUTPUT XXX;":MARKER:AVOLT CHANNEL1,2.75"
Query
:MARKer:AVOLt?
The AVOLt query returns the current voltage and channel selection for the A
marker.
Returned Format
[:MARKer:AVOLt]CHANnel<N>,<level><NL>
Example
OUTPUT XXX;":MARKER:AVOLT?"
MARKer Subsystem
AVOLt
32-6