Introduction
 
                                     
The EMO-500 is a Two Component Ratio and Flow Computer.  It is primarily designed 
for use as a two component, ratio monitoring unit but can also be used as a Two Channel 
Flow Rate Monitor and Totalizer. The EMO 500 has the added capability of current 
(4-20mA) and voltage (0-5V) analog output signals. These outputs can be used as a 
representation of a selectable range of functions or in a ratio linked, closed loop mode - 
Ratio Feedback Mode.  
 
The unit is powered by 110V AC but can be jumpered for 220V AC.   
 
The back panel provides these features: 
       
18V supply plus ground and input lines for two flow meters. 
      
4 programmable relay switched limits which can be used for warnings, alarms, or 
automatic shut-down control. 
      
5 "Ready to Hardwire" function controls. #'s 1 through 4 allow for remote 
operation of   resets, display, and Quick Programming.  # 5 will "enable" the main 
programming menu. 
     
RS-232 and RS-485 serial ports. 
                          
Analog outputs (4 - 20mA) and  (0 - 5V). 
 
Programming functions are shown in red on the keypad. 
 
All of the default program variables can be changed to alternative values through 
the keypad or by a host computer with an RS-232 serial port. There are security features 
to prevent unintended programming changes - for more information review the pages on 
Quick Programming and Full Programming.  The Quick Programming functions 
allocated to certain keys are indicated in red on the keypad. Keys F1 through F6 have 
multiple functions and are also used for the main programming purposes. The alternative 
function of each key when in Full Programming Mode is indicated by a banner on the 
keypad immediately above these specific keys.   
 
When programming is not enabled the F3/F4/F5 serve as Job Resets and keys 0 through9 
are used to select from the 11 operating displays shown on page 1.
 
IMPORTANT----IMPORTANT----IMPORTANT----IMPORTANT 
The higher flow side should be connected to  
flow meter A as the Ratio calculation is A/B 
IMPORTANT----IMPORTANT----IMPORTANT----IMPORTANT