ADIC Landscape Lighting 5.1 ユーザーズマニュアル

ページ / 14
VolServ Version 5.1 — 6-00572-01
Page 3 of 14
The following table describes known problems in this release.
Supported Libraries
The following libraries are supported in this release.
NOTE:
AIT is not currently supported as a pre-defined media type. At this time, an AIT library 
must be configured as an 8mm library.
In previous releases of VolServ, AML libraries with AIT-1 and/or AIT-2 drives may have used either one 
of the following DAS/AMU drive type designators:
• DC = AIT-1 and/or AIT-2 
• DM = AIT-1 and/or AIT-2
In VolServ release 5.1, due to a change in the AMU software, AML libraries with AIT-1 and/or AIT-2 
drives now use the following DAS/AMU drive type designators:
• DC = AIT-3
• DM = AIT-1 and/or AIT-2
Operating 
System
Change 
Requests
Description
IRIX 
4365
(07719)
When the operator’s console display goes down, the 
change archive 
parameters cannot be used to redisplay the console. 
Workaround: Select the specific library to be reconfigured, select <OK> to bring 
down the library, and then select <Done> so the operator’s console for that archive 
will reappear.
All
3669
(07723)
Library console does not emit a beep each time status is returned to it. 
4239
(07717)
The 
vsamlconfig
 command cannot handle hex numbers for drive slots that are 
printed from the AMU. 
Workaround: Configure the archive as a Scalar DLC archive.
4242
(07724)
If changing the AML configuration after initially configuring the library, the modified 
AMU information is unable to be uploaded to VolServ without deleting and 
recreating the library. 
Workaround: Configure the archive as a Scalar DLC archive.
4323
(11773)
Mixed media imports do not work for SCSI libraries.
6378
(08529)
Unable to mount tapes after recovery of offline robot.
6379
(11035)
If VolServ is started when the Scalar 1000 or the Scalar 10k archives are offline, 
the AMTask will not start. 
Workaround: Place the archives in an online state and cycle VolServ to get the 
AMTask running.