DKS Enterprises 9210 ユーザーズマニュアル

ページ / 57
2.2 Control 
Wiring 
Controls must be far enough from the gate so that the user is prevented from coming in 
contact with the gate while operating the controls. Outdoor or easily accessible controls 
should have a security feature to prevent unauthorized use. 
 
DOORKING, INC.,  INGLEWOOD, CA  90301
Title:
Date:
Rev.
Dwg. No.
Fire 
Dept
OPEN
CLOSE
STOP
A
Z
Call
Receiver
Telephone 
Entry
Stand-Alone
Card Reader
Stand-Alone
Keypad
Key
Switch
Roadway
Fence
Gate
A
1
2
3
4
Common
Relay
Power
123
45
6
789
1
0
1
1
1
2
1
3
1
4
15
16
1
7
1
8
4404-010
Circuit Board
S
e
c
onda
ry
 Entra
p
me
nt 
P
ro
te
c
tion
 Inputs
2
3
1
4
Radio receiver power only.  Power here is limited to 250 ma.
Partial open input.  Devices connected here will open the gate to the partial open limit setting only.
Reverse input functions only when gate is in the closing cycle.
Must use a DoorKing 3-button control station.  Others will not work.
B
C
D
D
Close direction contact sensor.
C
Open direction contact sensor.
B
Close direction non-contact sensor.
A
Open direction non-contact sensor.
Open contact 
sensor placed 
on fence.
C
Close contact sensor 
placed on gate.  
Wireless option 
available.
D
Diagram above is for illustration purposes.  The actual placement 
of the secondary protection devices is dependent on the specific 
installation requirements.
Secondary entrapment protection devices must be installed with 
this gate operator.  This protection may be provided by non-
contact or contact sensors, or a combination of both.  
Secondary device wiring shows inputs to the circuit board only.  
Photo-cells must be supplied with power.
Refer to the safety instructions in the front of this manual for 
more information.
Controls must be installed a minimum of 10-feet from the gate or 
installed in such a way that the person using the control cannot 
come in contact with the gate or gate operator.  
All inputs to the 4404 circuit board are Normally Open (N.O.).
11/07
A
4404-CNTRL-1
Model 9210, 9220, 9230, 9530
Control and Secondary Device Wiring
Open Photo
Close Photo
Open Edge
Close Edge
Common
Common
 
 
 
9210-065-H-8-08  
Page 
27