Dixi XWA11V ユーザーズマニュアル

ページ / 8
dIXEL

Operating Instructions XWA11V 
1598003200 
 
Weiss Instruments, Inc. 905 Waverly Ave. Holtsville, NY 11742  631-207-1200 www.weissinstruments.com 
 
XWA11V 
Walk-In Temp / Door /Alarm / Light Module 
 
 
1.  GENERAL DESCRIPTION 
Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature 
monitoring and alarming in a walk-in cooler or freezer. It is provided with two (2) Dry Contacts to control lights 
and an external alarms. It is provided with one (1) NTC probe input for temperature measurement. The unit 
has 2 Digital Inputs, one for a Door Switch and the 2
nd
 as an optional Panic Switch. See the catalog for 
optional accessories. One 5Pin Input allows the user to program the parameter list with a “Hot Key” (see 
section 9) 
 
Note: The default settings are listed in the back of this manual. They are set for Coolers (Medium 
Temp). For Freezers (Low Temp) you MUST Change the ALL and ALU settings. See Section 4.0 
 
2.  GENERAL WARNINGS 
2.1 
PLEASE READ BEFORE USING THIS MANUAL 
 
•  This  manual  is  part  of  the  product  and  should  be  kept  close  to  the  instrument  for  easy  and  quick 
reference. 
•  The instrument shall not be used for purposes different from those described hereunder. It cannot be used 
as a safety device. 
•  Check the application limits before proceeding.