Calculating the Tracking Filter Gains 
The tracking filter gains are system dependent, and need to be fine-tuned. This can be done by gathering 
and plotting filtered versus unfiltered data while moving the motor shaft manually. Best case scenario is 
super-imposing the filtered data on top of the unfiltered with minimum ripple and overshoot. 
 
The  empirical  equations  for  the  filter’s  proportional  and  integral  gains  (usually  acceptable  most 
applications) present a good starting point: 
F
f
: Filter Frequency (Hz) 
S
f
: Servo Frequency (Hz) 
 
                    
 
    
 
  (
 
 
 
)
 
  
  
 
 
                        
 
      (
 
 
 
)
 
  
  
 
 
Motors 1-8 Resolver Encoder Conversion Table Setup Example 
// Channel 1 
I8000= $F78B00 ; Resolver Counter Clockwise 
I8001= $478B10 ; Excitation address 
I8002= $000000 ; SIN/COS Bias word 
I8003=$D83503  ; Tracking filter from conversion location $3503 
I8004=$400 
; Maximum change in counts/cycle 
I8005=$80000 
; Proportional gain 
I8006=$0 
; Reserved setup word 
I8007=$1 
; Integral gain 
// Channel 2 
I8008=$F78B02  ; Resolver Counter Clockwise 
I8009=$478B10  ; Excitation address 
I8010=$000000  ; SIN/COS Bias word 
I8011=$D8350B  ; Tracking filter from conversion location $350B 
I8012=$400 
; Maximum change in counts/cycle 
I8013=$80000 
; Proportional gain 
I8014=$0 
; Reserved setup word 
I8015=$1 
; Integral gain 
// Channel 3 
I8016=$F78B04  ; Resolver Counter Clockwise 
I8017=$478B10  ; Excitation address 
I8018=$000000  ; SIN/COS Bias word 
I8019=$D83513  ; Tracking filter from conversion location $3513 
I8020=$400 
; Maximum change in counts/cycle 
I8021=$80000 
; Proportional gain 
I8022=$0 
; Reserved setup word 
I8023=$1 
; Integral gain 
// Channel 4 
I8024=$F78B06  ; Resolver Counter Clockwise 
I8025=$478B10  ; Excitation address 
I8026=$000000  ; SIN/COS Bias word 
I8027=$D8351B  ; Tracking filter from conversion location $351B 
I8028=$400 
; Maximum change in counts/cycle 
I8029=$80000 
; Proportional gain 
I8030=$0 
; Reserved setup word 
I8031=$1 
; Integral gain 
// Channel 5 
 
I8032=$F78B08  ; Resolver Counter Clockwise 
I8033=$478B10  ; Excitation address 
I8034=$000000  ; SIN/COS Bias word 
I8035=$D83523  ; Tracking filter from conversion location $3523 
I8036=$400 
; Maximum change in counts/cycle 
I8037=$80000 
; Proportional gain 
I8038=$0 
; Reserved setup word 
I8039=$1 
; Integral gain 
// Channel 6 
 
I8040=$F78B0A  ; Resolver Counter Clockwise 
I8041=$478B10  ; Excitation address