Click the Multifunction adapters view the card. If you want other
details, Select Properties.
Click Ports (COM & LPT) to view the COM numbers assigned by
Windows to the card.
You will have 1 new B&B Com port as shown.
Select Properties or double-click on the new com port.
Set DTR Operation
Set DTR Operation to Normal for RS-232.
Set DTR Operation to RS-485 Mode for 2-wire or 4-wire RS-485
operation.
Either setting can be used for RS-422.
The card jumpers must be set for the same mode. See Chapter 2.
The Default Com parameters are normally overridden by the
software application so it is not necessary to change them.
You can now remove the driver disc, close the Windows, and check
the new ports with your software.