35
MAINTENANCE & TROUBLESHOOTING
This section describes how to:
clean the lens
clean the fan intake filter
replace the projection lamp 
replace the batteries in the remote control
use the Kensington lock feature
troubleshoot the projector
Cleaning the Lens
Follow these steps to clean the projection lens:
1
Apply a non-abrasive camera lens cleaner to a soft, dry cloth.
Avoid using an excessive amount of cleaner.
Abrasive cleaners, solvents or other harsh chemicals might 
scratch the lens.
2
Lightly wipe the cleaning cloth over the lens.
3
If you don’t intend to use the projector immediately, replace 
the lens cap.
Cleaning the Fan Intake Filter
The fan intake filter on the bottom of the projector catches dust 
and particles in the air. If the filter becomes clogged, the projector 
does not cool properly and may malfunction. To prevent this, 
clean the filter after every 100 hours of use.
1
Turn off the power and unplug the power cord.
2
Remove the lamp door. 
Remove the screw on the outside of the lamp door.
Pull the lamp door up and remove it.