Bosch 2000 ユーザーズマニュアル

ページ / 72
2000 Series | Program Entry Guide | 3.0 
Reports 
EN | 13 
 
 
Bosch Security Systems | 7/05 | 35114F 
 
When set to 
Buzz, Report the system flashes the 
OK light at the keypad, sounds the trouble tone, and 
sends an AC Fail Report to the receiver. 
When set to 
Buzz, Tag-Along Rpt the system 
flashes the OK light and sounds the trouble tone at 
the keypad after 60 seconds. It sends an AC Fail 
Report to the receiver as a tag along with all reports 
sent to the receiver until AC restores. 
When set to 
No Buzz, Report the system flashes the 
OK light at the keypad and sends an AC Fail Report 
to the receiver. 
When set to 
No Buzz, Tag-Along Rpt the system 
flashes the OK light. It sends an AC Fail Report to 
the receiver as a tag along with all reports sent to the 
receiver until AC restores. 
8 Point User Flag 
Default: 
No
 
Selection: 
Yes, No
 
0 No 
1 Yes 
Set this prompt to Yes to send a flag with each 
Modem II Report that tells the D6500 to convert 
point numbers to Bosch Security System’s D8112 
style Zonex Format, and User ID numbers to D8112 