2000 Series | Program Entry Guide | 6.0 
Open/Close 
EN | 25 
 
Bosch Security Systems | 7/05 | 35114F 
 
6.2 Exit 
If you enable the 
Exit
 feature, pressing the [CLEAR] 
key at the keypad when the system is On with No 
Delay starts exit delay. The system sounds the exit 
delay tone (if 
Exit Tone 
is programmed Yes) and 
bypasses all points programmed for exit delay (Digit 1 
of point code is 6 or 8). 
The rest of the system 
remains On with No Delay. The tone and bypass 
remain until exit delay expires. The system returns to 
the 
On with No Delay
 state. The Exit feature allows 
one user to exit a system that is On with No Delay, 
leaving those left inside fully protected. 
If the user presses [CLEAR] during the exit delay, the 
system returns to On with No Delay. 
A faulted point (open door) at the end of exit delay 
creates an Exit Error alarm. 
If an alarm occurs within 2 minutes of the end of exit 
delay, the system sends an Alarm Recent Close 
Report. 
All Exit: Only allows users access to the Exit feature 
when the system is All On with No Delay (instant). 
Part Exit: Only allows users access to the Exit feature 
when the system is Part On with No Delay (instant).  
All & Part Exit: Allows users access to the Exit feature 
when either All or Part of the system is All On with 
No Delay (instant) or Part On with No Delay (instant).