Behringer DX052 ユーザーズマニュアル

ページ / 9
8
PRO MIXER DX052
These are the LINE inputs to connect a tape deck, CD or
MD player etc.
The GND connectors ground the turntables.
The  DX052  features  an  integrated  effects  loop  for  the
connection  of  an  external  effects  device/sampler.  The
MONITOR signal is taken at the SEND output and routed,
for  example,  to  a  reverb  processor.  Thus,  the  signal  at
the SEND connector is identical to the headphones signal.
The externally processed signal is added to the MASTER
output  signal  via  the  RETURN  connectors.  The  effect
signal volume may only be adjusted at the output control
of  the  effects  device  itself.
Fig. 3.2: PRO MIXER DXD052 rear panel connectors
The MASTER output is for connecting to an amplifier and
can be adjusted with the MASTER level control.
+
Always turn the power amps on last to avoid inrush
currents  that  can  easily  damage  your  speakers.
And,  to  avoid  sudden  and  unpleasant  surprises
for  your  ears,  make  sure  there  is  no  signal  at  the
DX052  before  turning  on  the  power  amps.  To  be
sure,  slide  all  the  faders  to  the  bottom  and  switch
all  controls  to  the  zero  position.
Using  the  TAPE  output  you  can  record  your  music  by
connecting  devices  such  as  tape  decks,  DAT  recorders
etc. Unlike the MASTER output, the output volume is fixed,
making it necessary for you to adjust the input level on the
recording  device.
The  POWER  switch  powers  the  DX052  on.  You  should
always make sure that the POWER switch is in the “Off”
position when initially connecting the unit to the mains.
+
Please  take  note:  Merely  switching  the  unit  off  does
not  mean  that  it  is  fully  disconnected  from  the
mains.  When  not  using  the  unit  for  prolonged
periods  of  time,  please  unplug  the  unit’s  power
cord  from  the  power  outlet.
FUSE HOLDER / VOLTAGE SETTING. Before connecting
the unit to the mains, ensure that the voltage setting matches
your  local  voltage.  Blown  fuses  should  only  be  replaced
by a fuse of the same type and rating. On some units, the
fuses holder can be switched to one of two positions, i.e.
230 V and 120 V. Please note: should you desire to operate
the  unit  outside  Europe  at  120  V,  a  higher  fuse  rating  is
required.
This  is  the  connector  for  the  power  cable.  This  is  where
the  advantage  of  a  sophisticated  internal  power  supply
can be seen: the pulse behaviour of each amplifying circuit
is  mainly  determined  by  the  voltage  reserves  available.
Each mixing console is equipped with numerous operational
amplifiers (op amps) to process line level signals. Due to
limited output of their power supplies, many mixing consoles
show  signs  of  “stress”  when  subjected  to  heavy  loads.
But  not  your  DX052:  the  sound  is  always  clear  and
transparent.
+
To  disconnect  power  from  main,  pull  out  the  main
cord  plug.  When  installing  the  product,  ensure  that
the  plug  is  easily  accessible.  If  mounting  in  a  rack,
ensure  that  the  mains  can  be  easily  disconnected
by  a  plug  or  by  an  all-pole  disconnect  switch  on  or
near  the  rack.
SERIAL NUMBER. Please take the time to complete and
return  the  warranty  card  within  14  days  of  the  date  of
purchase. 
Or, 
simply 
register 
online 
at
www.behringer.com.
4. SPECIFICATIONS
AUDIO INPUTS
Mic
40 dB Gain,
electronically balanced input stage
Phono 1 and 2
40 dB Gain, unbalanced inputs
Line 1 and 2
0 dB Gain, unbalanced inputs
Return
0 dB Gain, unbalanced input
AUDIO OUTPUTS
Master
max. +19 dBu @ +10 dB (Line in)
Tape
typ. 0 dBu
Send
typ. 0 dBu
Phones
max. 180 mW  @ 75 Ω / 1% THD
EQUALIZER
Stereo  Low
+12 dB/-32 dB @ 50 Hz
Stereo High
+12 dB/-32 dB @ 10 kHz
Mic  Low
+12 dB/-12 dB @ 50 Hz
Mic High
+12 dB/-12 dB @ 10 kHz
GENERAL
Signal-to-noise ratio
> 87 dBu (Line)
Crosstalk
> 70 dB (Line)
Distortion (THD)
< 0,05%
Frequency  response 10 Hz - 55 kHz +0/-3 dB
POWER SUPPLY
Mains voltages
USA/Canada
120 V~, 60 Hz
Europe/U.K./Australia
230 V~, 50 Hz
Japan
100 V~, 50 - 60 Hz
General export model
120/230 V~, 50 - 60 Hz
Power  consumption
13 W
Fuse
100 - 120 V~: T  500 mA  H
200 - 240 V~: T  250 mA  H
Mains connection
Standard IEC receptacle
DIMENSIONS/WEIGHT
Dimensions (H x W x D) approx. 4 3/10" (109.2 mm)
x 10 2/5" (264 mm)
x 12 2/5" (315 mm)
Weight
approx. 2.3 kg (5 1/16 lbs)
BEHRINGER makes every effort to ensure the highest standard of quality. Necessary
modifications are carried out without notice. Thus, the specifications and design of the device
may differ from the information given in this manual.
4. SPECIFICATIONS