Bosch Appliances Video Game Controller D9412GV2 ユーザーズマニュアル
![Bosch](https://files.manualsbrain.com/attachments/992db0bc6e4e397e226301d2fb6c3619baa82b37/common/fit/150/50/58e0935709337019a05abb2f9dc9475495d1a6775066eb5a72dc939185f4/brand_logo.png)
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN
EN | 64
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
Add User
View Log
Default:
P
Default:
E
Selection: Blank, E, or P
Selection: Blank, E, or P
Function
No.
No.
Function Name
Alternate
Keystroke
Keystroke
Function Name
Function
No.
No.
Alternate
Keystroke
Keystroke
18 Add
User
[COMMAND][5][6]
21 View
Log
(Menu function
only)
only)
Use this function to add or change pass codes, add or
change tokens or cards and Sub-users, and add or
change control panel authority levels (L##) by area.
change tokens or cards and Sub-users, and add or
change control panel authority levels (L##) by area.
Use this function to view all of the system events,
their time stamps, User IDs, or point numbers. User
Name and Point Text are not stored in the event log,
but they appear when the control panel matches them
with the User ID ### and the Point ###.
their time stamps, User IDs, or point numbers. User
Name and Point Text are not stored in the event log,
but they appear when the control panel matches them
with the User ID ### and the Point ###.
Del User
Default:
P
Each event appears on one line in the log. Any
information related to that event appears on a
separate line in the log.
information related to that event appears on a
separate line in the log.
Selection:
Blank, E, or P
Function Name
Function
No.
No.
Alternate
Keystroke
Keystroke
19 Delete
User
[COMMAND][5][3]
Because events in the log are not uniform in length,
the control panel can store from 500 to 1000 events.
the control panel can store from 500 to 1000 events.
Use this function to delete a user’s pass code and
tokens or cards. It does not delete user names.
tokens or cards. It does not delete user names.
Print Log
Default:
P
This function deletes the pass code,
Selection: Blank, E, or P
master user, and all sub-users
associated with the user number.
associated with the user number.
Function Name
Function
No.
No.
Alternate
Keystroke
Keystroke
Extend Close
22
Print Event Log
(Menu function
only)
only)
Default:
P
Use this function to print all the events stored in the
control panel beginning at the start date and ending
with the last event in the log.
control panel beginning at the start date and ending
with the last event in the log.
Selection:
Blank, E, or P
Function
No.
No.
Function Name
Alternate
Keystroke
Keystroke
User Cmd 7
20 Extend
Close
[COMMAND][5][1]
Default:
P
Use this function to change the expected closing time
for the area. The window cannot be adjusted until the
Close Early Begin time passes and the Closing
Window is active.
for the area. The window cannot be adjusted until the
Close Early Begin time passes and the Closing
Window is active.
Selection:
Blank, E, or P
Function Name
Function
No.
No.
Alternate
Keystroke
Keystroke
23
[COMMAND][7]
User COMMAND
7
7
Use this function to activate an alarm programmed in
COMMAND 7 in the RADXPNTS Handler.
COMMAND 7 in the RADXPNTS Handler.