Location Requirements
You will need
A location that allows for proper exhaust installation. See 
“Venting Requirements.”
A separate 30-amp circuit.
If you are using a power cord, a grounded electrical outlet 
located within 2 ft (61 cm) of either side of the dryer. See 
“Electrical Requirements.”
A sturdy floor to support the total dryer weight of 127 lbs  
(57.6 kg). The combined weight of a companion appliance 
should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire 
dryer. (If slope is greater than 1" [2.5 cm], install Extended 
Dryer Feet Kit, Part No. 279810.) Clothes may not tumble 
properly and automatic sensor cycles may not operate 
correctly if dryer is not level.
For a garage installation, you will need to place the dryer at 
least 18" (46 cm) above the floor. If using a pedestal, you will 
need 18" (46 cm) to the bottom of the dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will 
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes or 
sleeping quarters. Contact your local building inspector.
Installation clearances
The location must be large enough to allow the dryer door to 
open fully.
Dryer Dimensions
*Most installations require a minimum 5" (12.7 cm) clearance 
behind the dryer for the exhaust vent with elbow. See “Venting 
Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this 
dryer. This dryer has been tested for spacing of 0" (0 cm) 
clearance on the sides and rear. Recommended spacing should 
be considered for the following reasons:
Additional spacing should be considered for ease of 
installation and servicing.
Additional clearances might be required for wall, door and 
floor moldings.
Additional spacing should be considered on all sides of the 
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.
Companion appliance spacing should also be considered.
Custom undercounter installation - Dryer only
*Required spacing
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
     
36"
(91.4 cm)
     
50
¹⁄₂
"
(128.27 cm)
      
27"
(68.6 cm)
  
*28.65"
(72.77 cm)
2"*
(5 cm)
36" min
(91.4 cm)
1"*
(2.5 cm)
1"*
(2.5 cm)
27"
(68.6 cm)