HP 466133-041 ユーザーズマニュアル

ページ / 43
System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions (WxHxD)
7.87 x 16.81 x 24.13 in (200 x 427 x 613 mm) (W/O foot stand)
Weight
Weight
Weight
Weight (approximate)
Maximum:
(All hard drives, power
supplies and processors
installed)
30 kg
Minimum:
(One hard drive, power
supply and processor
installed)
16kg
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Range Input Voltage
90 to 135 VAC
180 to 265 VAC
Normal Line Voltage
100 to 127 VAC
200 to 240 VAC
Rated Input Current
load 10A at 100 to 127 VAC
5A at 200 to 240 VAC
Rated Input Frequency
47 to 66 Hz
Rated Input Power
(optional 750W RPS)
760 W Max
(940W) Max
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Maximum
(optional 750W RPS)
1814 BTU
(2243) BTU
Power Specifications
Power Specifications
Power Specifications
Power Specifications
To review typical power ratings use the Power Advisor which is available via
the online tool located at URL: 
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
Power
Power
Power
Power
(per power supply)
Rated Steady-State Power 460W (750W) at 100 VAC for system
460W (750W) at 200 VAC
Maximum Peak Power
460W (750W) at 100 VAC
460W (750W) at 200 VAC
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
50° to 95° F (10° to 35° C) at sea level with an
altitude derating of 1.8°F per 1,000 ft (1.0° C
per every 305 m) above seal level to a maximum
of 10,000 ft (3050 m) no direct sustained
sunlight . Maximum rate of change is 18°F/hr
(10°C/hr). The upper limit may be limited by the
type and number of options installed. System
performance may be reduced if operating with a
fan fault or above 86°F (30°C).
Non-Operating
-40° to 140° F (-30° to 60° C)
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 82.4°F
(28°C) maximum wet bulb temperature, non-
condensing.
Non-operating
**
10% to 95% relative humidity (Rh), 101.7°F
(38.7°C) maximum wet bulb temperature, non-
condensing.
Altitude
Altitude
Altitude
Altitude
Operating
10,000 ft (3000m). Maximum allowable altitude
change rate is 1°C per 300m.
Non-Operating
30,000 ft (9144m). Maximum allowable altitude
change rate is 1°C per 300m.
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWad) and declared
QuickSpecs
HP ProLiant ML150 Generation 6 (G6)
HP ProLiant ML150 Generation 6 (G6)
HP ProLiant ML150 Generation 6 (G6)
HP ProLiant ML150 Generation 6 (G6)
Technical Specifications
DA - 13249   North America — Version 29 — November 14, 2011
Page 39