Wind Crest WCL ユーザーズマニュアル

ページ / 6
 
 
  
.
 
 
 
 
 
NOTE:  Unit must be vented  
         to outside of the building. 
 
Prepare cabinet for mounting the hood per FIG-2. Use 
furring strips to level cabinet mounting surface with any 
cabinet trims. If your hoods accepts and your using dual 
internal ventilators refer to that instruction section. 
 
 
Attach and secure the transition to the hood with #6x3/8 
sheet metal screws and tape all joints prior to installing the 
hood. Attach hood to cabinet using #10 wood screws. 
Holes are located in the back panel and top panel of the 
hood for mounting. Use a minimum of four #10x3/4 wood 
screws to mount the hood. Longer screws are required if 
wall board or other nonstructural surfaces are used 
between the hood and main mounting surface which 
holes for additional mounting use appropriate anchors if 
not engaging the wood structure. 
HINT: If you find vibration noise is present because of 
cabinet structure use additional screws, in holes available, 
to rigidize mounting. 
 
 
Connect 120 volt, 60 Hz power through the conduit hole 
in top of hood, connecting to pigtail in hood junction box, 
white to white, black to black and connect green ground 
wire to the power supply ground wire per local codes.  
 
The recommended height from countertop or cooking 
surface to the bottom edge of the hood is 30 to 36 inches. 
Hood is recommended for use over domestic gas or 
electric appliances. Not recommended for use over solid 
fuel fired appliances. 
 
 
After installing the hood, install the internal blower 
(see FIG-1) unit by positioning the blower onto 
bracket-A, notched blower bracket will center 
blower. Rotate into position against hood top and 
secure with #8 sheet metal screws via bracket-B. To 
ease assembly you should predrive and then remove 
the #8 screws before installing the blower. If the 
remote ventilator is used see related instructions. The 
VEN100E/140E ventilator will require revision of 
some wiring in the hood receptacle box and possible 
modification of air discharge opening   See 
VEN100E/140E instructions.  
  NOTE: VEN140E requires a 20 AMP Power Supply. 
 
CAUTION: The hood is of sufficient weight that two 
installers are recommended to prevent injury or damage to 
the hood in handling. 
 
Turn the power on at the service entrance and check the 
operation of the controls. 
 
NOTE: be sure that all dampers are operating properly and 
are free to open. 
BACKDRAFT DAMPER: It is recommended that a backdraft damper be used 
in all installations. In cold weather installations it is necessary to use a backdraft 
damper to minimize backflow of cold air into room. A non-metallic thermal 
break should also be used to minimize conduction of outside temperatures 
through the ductwork. The thermal break should be located as close as possible 
to where the ducting enters the heated portion of the house. 
SAFTY WARNING: 
Turn off power circuit at 
the service entrance and 
lockout panel before 
wiring the range hood.