White Rodgers 1F83-0422 インストール手順
1
Blue Universal Thermostat with
Automatic Heat/Cool Changeover Option
Single Stage, Multi-Stage or Heat Pump
Installation and Operating Instructions for Models:
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING
THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.
CAREFULLY BEFORE INSTALLING OR OPERATING
THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.
Save these instructions for future use!
APPLICATIONS
1F83-0422 Thermostat
Model
Programming Choices
1F85-0422
5+1+1 Day 5+2 Day
Non-Programmable
1F83-0422
Non-Programmable
THERMOSTAT APPLICATION GUIDE
Description
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (No Aux. or Emergency Heat)
Yes
Heat Pump (with Aux. or Emergency Heat)
Yes
Systems with up to 2 Stages Heat, 2 Stages Cool
Yes
Heat Only Systems (with optional fan switch)
Yes
Millivolt Heat Only Systems – Floor or Wall Furnaces
Yes
Cool Only Systems
Yes
Gas or Oil Heat
Yes
Electric Furnace
Yes
Hydronic (Hot Water) Zone Heat – 2 Wires
Yes
Hydronic (Hot Water) Zone Heat – 3 Wires
Yes
PART NO. 37-7240B
Replaces 37-7240A
1316
SPECIFICATIONS
Electrical Rating:
Battery Power .................................................... mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire ................................................... 20 to 30 VAC
Terminal Load ........................................................... 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range ......................................................... 45° to 90°F (7° to 32°C)
Rated Differentials: Fast
Terminal Load ........................................................... 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range ......................................................... 45° to 90°F (7° to 32°C)
Rated Differentials: Fast
Med.
Slow
Heat (SS1, MS2) ............................................... 0.4 °F
0.6 °F
1.7 °F
Cool (SS1, MS2) ................................................ 0.9 °F
1.2 °F
1.7 °F
Heat Pump (HP1, HP2) ..................................... 0.9 °F
1.2 °F
1.7 °F
Emer (HP1, HP2) ............................................... 0.6 °F
–
1.7 °F
Operating Ambient .................................................... 32° to +105°F (0° to +41°C)
Operating Humidity ................................................... 90% non-condensing max.
Shipping Temperature Range ................................... -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ............................................ 3-7/8”H x 5-1/8”W x 1-1/4”D
Operating Humidity ................................................... 90% non-condensing max.
Shipping Temperature Range ................................... -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ............................................ 3-7/8”H x 5-1/8”W x 1-1/4”D
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this
product may replace a product that contains mercury.
This product does not contain mercury. However, this
product may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For prop-
er disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For prop-
er disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to
www.thermostat-recycle.org for loca-
tion to send product containing mercury.
CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
Index
Page
Installation
2
Wiring Connections
2
Thermostat Quick Reference
3
Installer Configuration Menu
4
Operating Your Thermostat
6
Programming
7
Troubleshooting
8
www.white-rodgers.com
www.emersonclimate.com