4. Remove the cap from the gas pressure regulator using a 
flat-blade screwdriver.
NOTE: Do not remove the spring beneath the cap.
5. Turn the cap over so the LP is visible.
6. Reinstall the cap.
To Convert Surface Burners
1. Remove burner grate, burner caps and burners. 
2. Locate LP gas orifice spuds for top burners in the literature 
bag included with the range. Two LP gas spuds are stamped 
“88” and two “78.”
3. Remove Natural gas orifice spuds using a 7 mm combination 
wrench.
4. Install LP gas orifice spuds using a 7 mm combination 
wrench.
NOTE: This range cooktop is equipped with 2 standard 
burners and 2 super burners. Spud size and location remain 
the same.
5. Place the Natural gas orifice spuds in the parts bag for future 
use and keep with the bag containing literature.
6. Reinstall burners, burner caps and burner grates.
A. Cap
A. Cap
A. Burner cap
B. Burner
A
A
A
B
A. Spud
B. Holder
A
B
2 super 
burners. Spud size/location rem ain the sam e.
Standard
Burner 78
Super
Burner 88
Standard
Burner 78
Super
Burner 88