Whirlpool MEDB850YG インストール手順

ページ / 20
4
Check code requirements. Some codes limit, or do not permit, 
installing dryer in garages, closets, mobile homes, or sleeping 
quarters. Contact your local building inspector.
DRYER DIMENSIONS
LOCATION REQUIREMENTS
You will need:
 
A location allowing for proper exhaust installation. See  
“Venting Requirements.”
 
A separate 30 amp circuit.
 
If using power supply cord, a grounded electrical outlet  
located within 2 ft. (610 mm) of either side of dryer. See 
“Electrical Requirements.”
 
Floor must support dryer weight of 200 lbs. (90.7 kg). Also 
consider weight of companion appliance.
 
Level floor with maximum slope of 1" (25 mm) under entire 
dryer. If slope is greater than 1" (25 mm), clothes may not 
tumble properly and automatic sensor cycles may not  
operate correctly. 
 
For a garage installation, place dryer at least 18" (457 mm) 
above floor. 
 
Steam models only: Cold water faucets located within 4 ft. 
(1.2 m) of the water fill valves, and water pressure of 20-100 
psi (137.9-689.6 kPa). You may use the water supply for your 
washer using the “Y” connector and short hose (if needed) 
which are provided.
For each arrangement, consider allowing more space for ease  
of installation and servicing; spacing for companion appliances  
and clearances for walls, doors, and floor moldings. Space  
must be large enough to allow door to fully open. Add spacing  
on all sides of dryer to reduce noise transfer. If a closet door  
or louvered door is installed, top and bottom air openings  
in door are required.
IMPORTANT: Do not operate, install, or store dryer where  
it will be exposed to water, weather, or at temperatures below  
45° F (7° C). Lower temperatures may cause dryer not to  
shut off at end of automatic sensor cycles, resulting in longer  
drying times.
INSTALLATION CLEARANCES
Location must be large enough to allow dryer door to open fully.
NOTE: Most installations require a minimum of 5" (127 mm) 
clearance behind dryer for exhaust vent with elbow. See “Venting 
Requirements.”
Side view with open door dimensions:
Back view:
Bottom view: