ELECTRICAL CONNECTION
Electrical Connection Options
Power Supply Cord
1.
 
Choose electrical connection type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to Power Supply Cord Connection.
3-wire direct connection:
Go to Direct Wire Connection.
4-wire direct connection:
Go to Direct Wire Connection.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to Power Supply Cord Connection.
NOTE:
 If local codes do not permit connection of a 
cabinet-ground conductor to neutral wire, go to “Optional 
3-wire connection.” This connection may be used with 
either a power supply cord or a direct wire connection.
2.
 
Remove terminal block cover
Before you start, disconnect power. Remove hold-down  
screw (D) and terminal block cover (A).
A. Terminal block cover 
B. External ground conductor screw
C. Center terminal block screw
D. Hold-down screw 
E. Neutral ground wire
F.  Hole below terminal block cover
E
C
B
F
D
A
Put power supply cord through the strain relief. Be sure that 
the wire insulation on the power supply cord is inside the 
strain relief. The strain relief should have a tight fit with the 
dryer cabinet and be in a horizontal position. Do not further 
tighten strain relief screws at this point.
Attach power supply cord  
to strain relief
2.
   
 
Attach power supply cord  
     strain relief
Remove the screws from a 3/4" (19 mm) UL listed strain relief 
(UL marking on strain relief). Put the tabs of the two clamp 
sections (C) into the hole below the terminal block opening 
(B) so that one tab is pointing up (A) and the other is pointing 
down (D), and hold in place. Tighten strain relief screws just 
enough to hold the two clamp sections (C) together.
1.
Power Supply Cord Strain Relief
POWER SUPPLY CORD CONNECTION
A
B
C
D