Western Digital 4TB Sentinel DS5100 Storage Server WDBYVE0040KBK ユーザーズマニュアル

ページ / 111
APPENDIX
86
WD SENTINEL DS5100/DS6100
ADMINISTRATOR AND MAINTENANCE GUIDE
5.
Carefully lower the fan plate toward you then lift the fan plate out of the unit (Figure 5).
Figure 5. Remove fan
6.
Gently place the replacement fan into the unit, ensuring that the orientation of the fan
is correct and that the fan interface connector is connected.
7.
Replace and tighten the four (4) Fan Plate mounting screws.
8.
Do not over-tighten the mounting screws.
9.
Reconnect all of the cables for the device.
10.
Restart the server.
WARNING!
Before removing the fan plate completely from the unit, detach the fan
interface connector from the back plane PCBA.
Important: Do not disassemble the fan. Return the entire assembly intact to WD, if
instructed to do so.