3.3 Contents of the Communication Port 
The contents of the modular connector signal are all the same from COM. PORT1 to COM. PORT4. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 RS-422A 
 RS-485A 
Pin No. 
Signal name 
Symbol 
 
Pin No. 
Signal name 
Symbol 
Receive data 
R (A) 
 
1 Send/receive 
data 
T/R 
(A) 
Receive data 
R (B) 
 
Send/receive data  T/R (B) 
3 Signal 
ground SG 
 3 Signal 
ground SG 
Send data 
T (B) 
 
Unused 
 
Send data 
T (A) 
 
Unused 
 
6 Signal 
ground SG 
 6 Signal 
ground SG 
 
The six-pin type modular connector should be used for the connection to the Z-COM 
module. (Recommended manufacturer and model: Hirose Electric, TM4P-66P) 
 
 
3.4  Example of Connection to PLC 
Up to four SRZ units can be multi-drop connected to one PLC communication port. 
Customer is requested to prepare a communication cable fit for the Z-COM to be connected by the PLC. 
 
Programmable 
controller (PLC) 
SRZ unit 1 
SRZ unit 2 
Connected to   
COM. PORT3 
Connected to 
communication port 
Connected to   
COM.PORT3 
Connected to 
COM.PORT4 
W-BF-02* 
SRZ unit 3 
(4 units maximum) 
W-BF-01* 
* Communication cable (RKC product) 
is sold separately. 
 
 
If communication errors occur frequently due to the operation environment or the 
communication distance, connect termination resistors to the Z-COM module and 
the other party unit. 
For termination resistor of Z-COM modules, see 3.6
 
Z-COM Module Termination 
Resistor. 
For the termination resistor of PLC side, see the PLC Instruction Manual.
 
 
 
RS-422A
 
 
MITSUBISHI MELSEC series 
 
R (A)
R (B)
SG
T (B)
T (A)
SG
RS-422A 
SDB 
SDA 
SG 
RDB 
RDA 
(
−) 
(+) 
(
−) 
(+) 
Shielded twisted pair wire 
Paired wire 
Z-COM module 
COM. PORT3 
PLC MITSUBISHI 
MELSEC series 
(Modular connector) 
 
 
When preparing a cable of connecting the computer link module belonging to the 
MITSUBISHI MELSEC series to our Z-COM module, cross each pair of wires the A 
and B terminal positions on their terminal boards are not symmetrical.
 
 
OMRON SYSMAC series 
 
R (A)
R (B)
SG
T (B)
T (A)
SG
SDB 
SDA 
SG 
RDB 
RDA 
RS-422A 
(
−) 
(+) 
(
−) 
(+) 
Shielded twisted pair wire 
Paired wire
Z-COM module 
COM. PORT3 
OMRON PLC 
SYSMAC series 
(Modular connector) 
 
 
 
RS-485 
 
MITSUBISHI MELSEC series 
 
SDB 
SDA 
SG 
RDB 
RDA 
*R
RS-485 
T/R (A) 
T/R (B) 
SG 
 
 
SG 
(
−)
(+)
PLC MITSUBISHI 
MELSEC series 
Shielded twisted 
pair wire 
Paired wire
Z-COM module 
COM. PORT3 
(Modular connector) 
*R: Termination resistor 
(PLC side) 
 
 
 
3.5  Example of Connection to the Host Computer 
Up to 16 SRZ units can be connected to a host computer communication port. The communication 
cable must be provided by the customer. 
 
SRZ unit 1 
SRZ unit 2 
Connected to 
COM.PORT1 
RS-232C/RS-422A converter 
COM-A (RKC product) 
W-BF-02* 
Host computer 
Connected to 
communication 
connector 
Connected to   
COM.PORT1 
Connected to   
COM.PORT2 
W-BF-28* 
Connected to 
COM.PORT1
Connected to 
COM.PORT2
W-BF-02* 
SRZ unit 3
(16 units maximum)
RS-422A 
RS-232C 
* Communication cable (RKC product) 
is sold separately. 
 
If communication errors occur frequently due to the operation environment or the 
communication distance, connect termination resistors to the Z-COM module and 
the other party unit.
 
For termination resistor of Z-COM modules, see 3.6 Z-COM Module Termination 
Resistor.
 
For the termination resistor of PLC side, see the PLC Instruction Manual. 
 
 
RS-422A
 
 
When the interface of host computer is RS-422A 
 
R (A)
R (B)
SG
T (B)
T (A)
SG
T (A)
T (B)
SG  
R (A)
R (B)
RS-422A 
(
−)
(+)
(
−)
(+)
Shielded twisted pair wire 
Paired wire
Host computer 
Z-COM module 
COM. PORT1 
(Modular connector) 
 
 
When the interface of host computer is RS-232C (RS-232C 
 RS-422A) 
When the interface of host computer is RS-232C, connect the RS-232C/RS-422A converter 
between the host computer and the Z-COM. 
 
COM 
Host 
computer
Z-COM 
RS-232C/RS-422A converter 
COM-A (RKC product) 
RS-422A 
RS-232C
D-SUB 9P
connector 
Connected to   
COM. PORT1 
Connected to   
COM. PORT2 
Connected to 
communication 
connector
W-BF-28* 
W-BF-02* 
Connected to   
COM. PORT1 
*
 
Communication cable (RKC product) is 
sold separately. 
 
 
When the host computer has a USB connector 
When the host computer has a USB connector, connect the USB communication converter between 
the host computer and the Z-COM module. 
 
Host computer 
USB communication 
converter COM-K 
(RKC product) 
Connected to USB 
port of a personal 
computer
 
USB cable
(COM-K accessory) 
Connected to 
USB connector 
of COM-K 
The termination 
resistor is built 
in to the 
COM-K.
 
RS-422A
1
SG
2
4
3
5
T (A)
T (B)
Shielded twisted 
pair wire 
Z-COM module 
COM. PORT1 
(Modular connector) 
1
R (A)
R (B)
SG
T (B)
T (A)
SG
2
3
4
5
6
R (A)
R (B)
Paired wire
(
−)
(+)
(
−)
(+)
 
 
 
Loader communication 
Connect a USB communication converter between the host computer and the Z-COM module.
 
 
 
Host computer 
USB communication converter 
COM-K (RKC product) 
Connected to 
USB port of a 
personal computer
Connected to 
USB connecter
The termination 
resistor is built in  
to the COM-K. 
COM 
Loader communication cable
(W-BV-01) 
[Option] 
Connected to loader 
communication connector 
of the Z-COM module 
Connected to 
loader 
communication 
connecter 
USB cable (COM-K accessory)
 
 
3.6 Z-COM Module Termination Resistor 
If communication errors occur frequently due to the operation environment or the communication 
distance, connect termination resistors to the Z-COM module and the other party unit. 
 
When multidrop connected, 
connect a termination resistor to 
the Z-COM module at the farthest 
end of the communication line.
 
• When the COM. PORT1 is used: 
 
Insert the termination resistor to COM. PORT2.
 
W-BW-01 (For RS-485) 
W-BW-02 (For RS-422A) 
[120 
Ω 1/2 
W]
 
• When the COM. PORT3 is used: 
 
Insert the termination resistor to COM. PORT4.
Termination resistor connector 
(Sold separately) 
 
4. SPECIFICATIONS 
 
PLC communication 
Interface: 
Base on RS-422A, EIA standard 
Base on RS-485, EIA standard 
Protocol: 
•  MITSUBISHI MELSEC series special protocol (type 4) 
−  A compatible, 1C frame, ACPU common command (WR/WW) 
(A series, FX2N/FX2NC series or FX3U/FX3UC series) 
−  A compatible, 1C frame, AnA/AnUCPU common command (QR/QW) 
(AnA/QnA series, Q series) 
D register, R register, W register, ZR register 
•  OMRON SYSMAC series special protocol 
−  C mode command (RD/WD) 
DM register, EM register (Specify the bank No. +10), 
EM register (Specify the current bank) 
Communication speed: 4800 bps, 9600 bps, 19200 bps, 38400 bps 
Maximum connections: Four SRZ units per communication port of PLC 
Usable PLC type: 
•  MITSUBISHI MELSEC series 
−  Computer link unit 
AJ71UC24, A1SJ71UC24-R4, A1SJ71C24-R4, etc. 
The unit which AnA/AnUCPU common command (type 4) can use. 
− Serial communication unit 
AJ71QC24N, A1SJ71QC24N, QJ71C24, etc. 
The unit which AnA/AnUCPU common command (type 4) can use. 
− Adapter 
FX0N-485ADP, FX2NC-485ADP, FX3U-485ADP 
−  Expanded function board 
FX2N-485BD, FX3U-485-BD 
•  OMRON SYSMAC series 
−  High-order link unit 
C200H-LK202-V1, C500-LK203, C120-LK202-V1 
(SYSMAC C series), etc. 
−  CPU unit with a built-in communication port 
CPU unit of SYSMAC CS1 series and CJ1 series 
− Serial communication board 
CS1W-SCB41 (SYSMAC CS1 series), 
CJ1W-SCU41 (SYSMAC CJ1 series), etc.
 
 
 
Host communication 
Interface: 
Base on RS-422A, EIA standard 
Base on RS-485, EIA standard 
Protocol: 
RKC communication or Modbus-RTU 
Communication speed: 
4800 bps, 9600 bps, 19200 bps, 38400 bps 
Maximum connections: 
Sixteen SRZ units per communication port of Host computer 
 
 
General specifications 
Power supply voltage: 
24 V DC 
Power supply voltage range: 
21.6 V to DC 26.4 V DC 
[Including power supply voltage variation] 
Current consumption: 
30 mA max. 
Rush current: 10 A or less 
Allowable ambient temperature: 
−10 to +50 °C 
Allowable ambient humidity: 
5 to 95 %RH 
(Absolute humidity: MAX.W.C 29.3 g/m
3
 dry air at 101.3 kPa) 
Installation environment conditions:  Indoor use 
Altitude up to 2000 m 
Weight: 
Approx. 110 g 
 
 
Standard 
Safety standard:  UL: 
UL61010-1 
cUL:  CAN/CSA-C22.2 No. 61010-1 
CE marking: 
LVD:  EN61010-1 
 
OVERVOLTAGE CATEGORY II, POLLUTION DEGREE 2, 
 
Class II (Reinforced insulation) 
EMC: EN61326 
C-Tick: 
AS/NZS CISPR11 (equivalent to EN55011) 
 
 
5. MODEL CODE 
Z - C O M - A   -  
 
 
(1) (2) (3) (4) (5) (6)
 
Code (4) to (6) are for quick start 
codes to specify software configurable 
settings. If not specified, these codes 
will not be printed on labels and all 
settings will be factory default. 
 
(1)  Communication 1 (COM. PORT1, COM. PORT2) 
4: RS-422A 
5: RS-485 
 
(2)  Communication 2 (COM. PORT3, COM. PORT4) 
4: RS-422A 
5: RS-485 
 
(3)  Quick start code (Communication protocol selection) 
N*: No quick start code (Configured as factory default) 
1:  Specify quick start code 1
 
 
(4)  Communication 1 protocol (COM. PORT1, COM. PORT2) [Quick start code 1] 
No code:  No specify quick start code 
1: RKC 
communication (ANSI X3.28) 
2: Modbus 
 
(5)  Communication 2 protocol (COM. PORT3, COM. PORT4) [Quick start code 1] 
No code:  No specify quick start code 
1: RKC 
communication (ANSI X3.28) 
2: Modbus 
3: 
MITSUBISHI MELSEC series special protocol (PLC communication) 
AnA/AnUCPU common command (QR/QW)
 
(AnA/QnA series, Q series)
 
4: 
OMRON SYSMAC series special protocol (PLC communication) 
5: 
MITSUBISHI MELSEC series special protocol (PLC communication) 
 
ACPU common command (WR/WW)
 
 
(A series, FX2N/FX2NC series or FX3U/FX3UC series) 
 
(6)  The number of the correspondence channels (Only PLC communication) 
No code:  No specify quick start code 
A: 16 
CH 
B: 32 
CH 
C: 48 
CH 
D: 64 
CH 
 
* F
actory set value when there is not specification of quick start code
:  
Communication 1/communication 2   
RKC communication 
The number of the correspondence channels: 64 CH 
 
COM. PORT1 
Communication 1 
Communication 2 
COM. PORT3 
COM. PORT2 
COM. PORT4 
Z-COM module internal block diagram 
The  Z-COM module’s 
COM.PORT is internally 
connected. 
Two systems are used 
for communication. 
Modular connector
 
Pin number 
Communication 
port 
COM. PORT1 
 
 
COM. PORT2 
Communication 1 
Connector for Host 
computer or Operation 
panel connection 
 
[RS-422A/RS-485] 
Communication 2 
Connector for PLC, Host 
computer or Operation 
panel connection 
 
[RS-422A/RS-485] 
Communication 
port 
COM. PORT3 
 
 
COM. PORT4