blowER liMit coNtRol sEttiNgs
The temperature in the plenum of the warm air fur-
nace at which the blower turns on or off, is controlled by 
the blower limit control settings.  Indicators (see figures 
7 & 8, page 10) in the control may be adjusted through 
their  entire  range  of  settings  to  achieve  the  desired 
warm air output (see figure 15).
Move  both  pointers  towards  the  right  (counter 
clockwise) – this increases the temperature setting at 
which the blower will turn on and off. Move both pointers 
towards the left (clockwise) – this decreases the on/off 
temperature setting. Increasing the distance between 
the pointers increases the time the blower will run on 
each warm air cycle.
Fig. 15 – Blower Limit Control Settings
powER FAilURE iNstRUctioNs
Operation during power loss:
Do not expect to keep home at normal temperatures.
1.  Remove air filter if provided.
2.  Reduce fire to a low burn.
3.  Set bimetal thermostat on LOW setting and set spin 
draft on ash door to a minimum of one turn open. 
4.  Do not load fuel above bottom of feed door.
blowER FAN AND MotoR cARE
Oil blower motor(s) twice a year. Add five drops of 
light weight (SAE 20) oil to each oiler tube. If the blower 
and fan accumulate moderate to heavy dust, vacuum, 
wipe and/or blow dust from motor housing and fan.