Siemens AC75 ユーザーズマニュアル
AC75 AT Command Set
8.11 AT^SMONG
s
AC75_ATC_V01.002
Page 215 of 569
10/30/06
Confidential / Released
8.11
AT^SMONG GPRS Monitor
The
command supplies GPRS specific cell information. There are two ways to retrieve the informa-
tion: once on request by using the execute command or automatically every
seconds by using the
write command. To stop the periodic presentation type "AT" or "at".
Syntax
Parameter Description
1
Cell Info Table
Display period in seconds
If
issued).
If
is given, the cell data will be listed repeatedly on 10 data lines. Every 10
th
data line is followed by
the header, simply to repeat the column titles.
1...100
1...100
Test Command
AT^SMONG=?
Response(s)
^SMONG:
(list of supported
s), (list of supported
s)
OK
ERROR
+CME ERROR
Exec Command
AT^SMONG
Response(s)
GPRS Monitor
Cell Info Table (see: Section
Cell Info Table (see: Section
)
OK
ERROR
+CME ERROR
Write Command
]
Response(s)
^SMONG:
GPRS Monitor
Cell Info Table (see: Section
)
OK
ERROR
+CME ERROR
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
SIEMENS
+
+
+
+
+
+
+
-
-
-
<table>
(num)
<period>
(num)