19.9
AT^SWDAC Configure and Read PWM Signal for DAC
The 
 controls the PWM (Pulse Width Modulation) signals generated by means of the DAC_OUT pin
of the AC75 Module. The DAC_OUT pin is not available on the the AC75 Terminal, therefore 
 applies
only to the AC75 Module. 
Syntax
Parameter Description
Duty cycle in percentage steps
0...100
Open or close DAC
0
Close DAC
1
Open DAC
PWM frequency
0
320 Hz (accuracy of 1 percentage step)
1
970 Hz (accuracy of 3 percentage steps)
2
8,125 Hz (accuracy of 1 percentage step)
3
16,250 Hz (accuracy of 1 percentage step)
Test Command
AT^SWDAC=?
Response(s)
^SWDAC:
(list of supporte
s), (list of supported 
s), (list of supported 
s)
OK
Read Command
AT^SWDAC?
Response(s)
OK
ERROR
+CME ERROR: <err>
Write Command
[, 
]]
Response(s)
OK
ERROR
+CME ERROR: <err>