On-Q/Legrand HMS 1100 ユーザーズマニュアル

ページ / 88
Page 18 
 
HMS 1100  
 
Modules / Output  
Unit Numbers 
 
Unit Numbers 
 
  193 -  208 
 
X-10 modules 1 - 16, House Code X+12 
 
     
 
 
  209 -  224 
 
X-10 modules 1 - 16, House Code X+13 
 
     
 
 
 (193 -  223) 
 
ALC addresses 1-31, Module 2 - Branch 1 * 
 
  225 -  240 
 
X-10 modules 1 - 16, House Code X+14 
 
     
 
 
  241 -  256 
 
X-10 modules 1 - 16, House Code X+15 
 
 
 (225 -  255) 
 
ALC addresses 1-31, Module 2 - Branch 2 * 
 
  257 -  272 
 
Outputs 1-16, 1st Expansion Enclosure * 
 
  273 -  288 
 
Outputs 1-16, 2nd Expansion Enclosure * 
 
  289 -  304 
 
Outputs 1-16, 3rd Expansion Enclosure * 
 
  305 -  320 
 
Outputs 1-16, 4th Expansion Enclosure * 
 
  321 -  336 
 
Outputs 1-16, 5th Expansion Enclosure * 
 
  337 -  352 
 
Outputs 1-16, 6th Expansion Enclosure * 
 
  353 -  368 
 
Outputs 1-16, 7th Expansion Enclosure * 
 
  369 -  384 
 
Outputs 1-16, 8th Expansion Enclosure * 
 
  385 -  392 
 
Voltage Outputs (1-8), Fully Configurable 
 
  393 -  511 
 
Internal Flags 
 
 
Notes:  
 
"X"  Represents the House Code setting on the HMS 1100. 
 
"*" If 
used. 
 
Scrolling Through Names 
  
The HMS 1100 stores names for Units, Zones, Buttons, Codes, Temperatures, and Messages so that you don't have to remember 
that "UNIT 5" is the "DEN LIGHT" and "ZONE 1" is the "FRONT DOOR".  In general, any time you enter a unit, zone, button, 
code, temperature, or message number, you can press the down arrow key to display its name, then use the up and down arrow 
keys to scroll through the list of other names.  This is true when entering commands and programming on the console.