On-Q/Legrand HMS 1100 ユーザーズマニュアル

ページ / 88
Page 62 
 
Enable Freeze Alarm 
 
If there are one or more Thermostat in a system, they can also be used to detect a freeze condition - See Freeze Alarm
 
The default for Enabled Freeze Alarm is No. 
 
Flash For Alarm 
 
You may enter one unit number that will flash on and off continuously when the alarm is activated.  This should be an outside 
light to alert neighbors and police to your property if the alarm is activated. 
 
The default Flash For Alarm is Unit 2.  You may enter one number for the unit number you wish to have flash, or ' 0 ' for none. 
 
X-10 House Code 1 Format 
 
House Code 1 can be configured to use the Standard (Preset Dim Command), Extended Code (Level Command), and Lightolier's 
Compose Mode transmission format.  
 
 
X-10 HC 1 FORMAT:      1 
 
1=EXTENDED      #=CHNG 
 
To change format for House Code 1, press the ' # ' key, then use the arrow keys to scroll through the list of formats.  Press the ' # ' 
key to select a new type
.
  
 
FORMAT NUMBER 
DESCRIPTION 
 
STANDARD 
 
 
 
Preset Dim Command (X-10, X-10 Pro, PCS, etc.) 
EXTENDED 
 
 
 
Extended Code Level Command (Leviton) 
COMPOSE 
   2 
Compose 
Mode 
(Lightolier's 
Compose) 
 
The default setting for X-10 HC 1 Format is 1. 
 
X-10 House Codes 2-16 Format 
 
House Codes 2-16 can be configured to use the Standard (Preset Dim Command), Extended Code (Level Command), and 
Lightolier's Compose Mode transmission format. 
 
 
X-10 HC 2 FORMAT:      1 
 
1=EXTENDED      #=CHNG 
 
The default setting for X-10 HC 2-16 Format is 1. 
 
House Code 1 X-10 All Off 
 
This feature allows you to choose if X-10 House Code 1 or ALC Branch 1 will respond to All Off commands. 
 
 
 
 
HC 1 X-10 ALL OFF:      1
 
 
 
 
0=NO 1=YES              
 
To turn HC 1 All Off feature On, press 1 then ' # '.  To turn HC 1 All Off feature Off, press the 0 key, then ' # '. 
 
The default setting for HC 1 X-10 All Off is Yes. 
 
House Code 1 X-10 All On 
 
This feature allows you to choose if X-10 House Code 1 or ALC Branch 1 will respond to All On commands. 
 
 
 
 
HC 1 X-10 ALL ON:       1
 
 
 
 
0=NO 1=YES