Page 65 
 
   DST 
START 
WEEKEND:
 
 
 
 
FIRST SUNDAY    #=CHNG 
 
 
 
 
DST END MONTH:        10
 
 
 
 
1-12  0=DISABLE        
 
 
 
 
DST END WEEKEND:       
 
 
 
 
LAST SUNDAY     #=CHNG 
 
 
Set the value for DST Start and End Months to "0" if Daylight Savings Time does not apply to your region, or to disable this 
automatic time update feature. 
 
The DST Start and End Weekend takes place on the specified Sunday (1-7) at 2:00 AM. 
 
To change the DST Start or End Weekend, press the ' # ' key, then use the arrow keys to scroll through the list.  Press the ' # ' key 
to make the new selection
.
  
 
NUMBER   DESCRIPTION 
 
 1 
 First 
Sunday 
 2 
 Second 
Sunday 
 3 
 Third 
Sunday 
 4 
 Fourth 
Sunday 
 5 
 Last 
Sunday 
 
 
Next to Last Sunday 
 
 
Third from Last Sunday 
 
Controller IP Address 
 
The controller’s local network IP address is used to identify the HMS 1100 controller on the network.  To view and assign the 
controller’s local network IP address, from the Set Up menu, press the 6 (MISC) key.  Using the down arrow key (
), scroll to the 
following menu item: 
 
   IP 
ADDRESS 
 
 
 
192.168.0.101          
 
The format of the IP address is a 32-bit numeric address written as four numbers separated by periods.  An IP address has two 
components, the network address, and the host address.  The first two numbers (e.g. 192.168) represent the Class B network 
address and must be the same as the first two numbers of your local network.  The second two numbers (e.g. 0.101) identify a 
particular host on the local network and may be assigned at random as long as each device on the local network has a unique 
address.  Each number can be 0 to 255.  Enter the 1, 2, or 3 digit number followed by the “#” key to move to the next number.  
After the 4
th
 number has been entered, press the “#” key to store the IP address. 
 
Controller Port Number 
 
The controller’s local network port number identifies the logical channel to the HMS 1100 controller.  For example, port 80 is 
used for HTTP traffic; the controller’s local network port number is used for HMS-Link traffic.  To view and assign the 
controller’s local network port number, from the previous Setup item (IP ADDRESS), press the down arrow key (
). 
 
 
 
 
PORT NUMBER         4369 
 
 
 
0-65535                
 
In most installations, the default port number can remain the same.  Port numbers range from 0 to 65535.  To change the port 
number, enter the new port number followed by the “#” key to store the port number.  Port numbers 0 to 1024 are reserved for 
designated services and should not be used.