Intel SC5400 ユーザーズマニュアル

ページ / 146
12
Intel® Server Chassis SC5400 User’s Guide
Standard and Optional Hot-swap Drive Bays
One bay supporting six cabled drives ships with the standard chassis. Optional hot swap 
drive bays may replace the six-drive fixed drive bay. An optional four-drive fixed drive 
bay (for cabled drives) is available. No tools are required to replace the fixed drive bays. 
Optional four-drive and six-drive SAS/SATA and SCSI hot-swap drive bays are available.
For instructions on installing hard drives, see 
.
Note: Drives can consume up to 17 watts of power each. Drives must be specified to run at a 
maximum ambient temperature of 45C.
The Intel
® 
Server Chassis SC5400 does not support all SAS, SATA, or SCSI hard drives. 
 for an Internet link to a list of 
supported hardware.
Floppy / CD-ROM / DVD-ROM Slimline Carriers
For installation instructions on installing a floppy drive see 
. For installation instructions on 
installing a CD-ROM drive or DVD-ROM drive, see 
To use one of the drives provided by Intel, use the following order codes:
Slimline CD-ROM Drive: AXXSCD
Slimline DVD/CDR Drive: AXXDVDCDR
Slimline Floppy Drive: AXXCDUSBFDBRK
Note: The Intel
® 
Server Chassis SC5400 does not support all slimline floppy, CD-ROM or 
DVD-ROM hard drives. See 
Internet link to a list of supported hardware. Intel provides accessory kits for these drives.