23
Replacing a Fixed Fan (Intel
® 
Server Chassis 
SC5400Base SC5400BRP only)
Note: This procedure applies only to the Intel
® 
Server Chassis SC5400 BASE and Intel
® 
Server 
Chassis SC5400BRP configurations. The Intel
® 
Server Chassis SC5400LX and 
SC5400LXi ship with hot-swap fans.
1. Observe the safety and ESD precautions at the beginning of this book. 
2. Power down the server and unplug all peripheral devices and the AC power cable. 
3. Remove the chassis cover. For instructions, se
.
4. Disconnect the appropriate fan power cable from the server board.
5. Remove the 92-mm (see letter “A” in the following figure) or 120-mm (see letter 
“B”) fixed fan from its snap-in bracket.
Figure 14. Removing a Fixed Fan
6. Install new 92-mm or 120-mm fixed fan.
7. Connect fan power cable to the server board. See the Intel
®
 server board Quick 
Start User’s Guide or User Guide for appropriate connection location. 
8. Re-install the chassis cover. For instructions, see 
9. Plug all peripheral devices and the AC power cable into the server and then power 
up the server.
TP00991
B
A
120-mm
Fixed Fan
92-mm
Fixed Fan