Elation Professional Boating Equipment E Spot LED ユーザーズマニュアル

ページ / 52
 
 
E  SPOT  LED™ 
©Elation Professional, Los Angeles Ca. 
42 
 
www.ElationLighting.com
   
 
11. ERROR CODES: 
 
When  power  is  applied,  the  unit  will  automatically  enter  a  “reset/test”  mode.  This  mode 
brings all the internal motors to a home position. If there is an internal problem with one or 
more of the motors an error code will flash in the display in the form of “XXer” were as XX will 
represent a function number. For example, when the display shows “0Er,” it means there is 
some type of error with the Pan motor. If there are multiple errors during the start-up process 
they will all flash in the display. For example: if the fixtures has errors on channel 1, channel 
2,  and  channel  5  all  at  the  same  time,  you  will  see  the  error  message  “01Er”,  “02Er,” 
and ”05Er” flash repeated 5 times.   
 
If  an  error  does  occur  during  the  initial  start-up  procedure  the  fixture  will  self-generate  a 
second reset signal and try to realign all the motors and correct the errors, if the error persist 
after a second attempt a third attempt will be made.   
 
If  after  a  third  attempt  all  the  errors  have  not  been  corrected  the  fixture  will  make  the 
following determinations: 1) 3 or more errors - The fixture cannot function properly with three 
or  more  errors  therefore  the  fixture  will  place  itself  in  a  stand-by  mode  until  subsequent 
repairs can be made. 2) Less than 3 errors - The fixture has less than 3 errors, therefore 
most other functions will work properly. The fixture will attempt to operate normally until the 
errors  can  be  correct  by  a  technician.  The  errors  in  question  will  remain  flashing  in  the 
display as a reminder of internal errors.       
 
PAN  Error:  The  yoke  is  not  located  in  the  default  position  after  start-up  or  after  a  reset 
command.  This  message  will  appear  after  a  fixture  reset  if  the  pan’s  magnetic-indexing 
circuit malfunctions (sensor failed or magnet is missing) or there is a motor failure (defective 
motor or a defective motor IC drive on the main PCB). This error may also be displayed if the 
head/yoke was blocked during a reset function. 
 
TILT  Error:  This  message  will  appear  after  a  fixture  reset  if  the  tilt’s  magnetic-indexing 
circuit malfunctions (sensor failed or magnet is missing) or there is a motor failure (defective 
motor or a defective motor IC drive on the main PCB). This error may also be displayed if the 
head was blocked during a reset function.