Avery ALS 330/430 ユーザーズマニュアル

ページ / 95
Operators Manual 
ALS 330/430 
Release 4/06 
Page 44 
Configuration menu 
6.1  Handling the menu 
The menu structure is shown in the following table. By means of the key PRIOR you switch to 
the prior function, and with the key NEXT to the next following function in the menu. 
If you press the key ENTER the current parameter value of a function is shown. The current 
parameter value can be changed with the keys PRIOR FUNCTION or NEXT FUNCTION. 
Values are stored by pressing the key ENTER. 
 
Display 
Function of the parameter 
Possible data entry 
DTST 
Test run without labels 
 
P_S_ 
Product sensor detects at leading or 
trailing edge of product 
LEDG, TEDG 
MACH 
Machine type 
230, 720, 330, 430 
MDIR 
Motor running direction for left or right 
hand  
<----   ---> 
MLAB 
Handling of missing label 
NONE, WARN, ERR1, ERR2, 
ERR3 
APSF 
Automatic product speed follower 
YES, NO 
APPL 
Direct dispense mode, or applicators 
DIR, ASA, EP, RVEP 
I_CH 
Test of inputs 
 
O_CH 
Test of outputs 
 
FACT 
Reset of all parameters to default values 
YES, NO 
BAUD 
Baudrate of the interface 
NONE, 300 to 192% 
PARI 
Parity bit 
NO, 0PRT, ODD, EVEN 
SBIT 
Number of Stop bits 
1 bit, 2 bit 
DBIT 
Number of data bits 
7 bit, 8 bit 
RECY 
Recycle (simulates max labels/min) 
see text 
DIST 
Distance label sensor to dispensing edge
10 ... 999 mm 
LABC 
Number of dispensed labels 
see text 
QUIT  
Return to extended standard menu