AVerMedia Technologies EYES PRO MP3000 ユーザーズマニュアル

ページ / 81
AVerMedia User’s Manual 
EYES Pro/MP2016/MP3000/MP5000  
 
9
Cameras need to be installed according to the numerical order displayed 
on the diagrams above.  Whether you have one, two, three or four 
video cards, the pattern is the same - cameras will be installed from 
left to right starting with the top row for EYES Pro
 and from top 
to bottom beginning with the left-most column for 
MP2016/MP3000/MP5000. 
 
1.8 Connecting External Sensor/Relay  
Each system can come with optional External I/O Boxes and D-type 15-
pin connector cables enabling you to connect sensor inputs and relay 
outputs.  The pin signals and specifications for the external I/O Box and 
the D-type 15-pin connectors are described below. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
D-type 15-pin Connector Cable 
External I/O Box 
Video Card 
External I/O Box 
Relay Outputs 3 
Sensor Input 3 
Relay Output 2 
Sensor Input 2 
Sensor Input 1 
Relay Output 1 
D-type 15-pin connector 
Sensor Input 4 
AVerMedia User’s Manual 
EYES Pro/MP2016/MP3000/MP5000  
 
10
Sensor Input Specification 
 
 
 
 
 
 
 
 
 
 
 
 
Relay Output Specification 
Surge strength: 1500 VAC 
Nominal power 200mw ~ 360mw  
Operating power 110mw ~ 200mw  
 
COIL RATINGS (at 20
 o
C) 
Coil Nominal 
Voltage  
(VDC) 
Coil 
Resistance ( 
10% ) 
Pick-up 
Voltage 
(VDC) 
Drop-Out 
Voltage  
(VDC) 
Nominal 
Current 
(mA) 
5 
125 
3.75 
0.5 
40 
* Max Continuous Voltage at 20
o
C : 110% of Coil Nominal Voltage