Bosch Appliances Security Camera X40 ユーザーズマニュアル

ページ / 12
EN | 10
Quick Installation Guide | VideoJet X10/X20/X40
Bosch Security Systems | 2006-12 | V2.5
7. Configure the IP Address
• Install the program Configuration Manager from the CD-ROM provided. If the CD-ROM 
does not start automatically doubleclick the index.htm file.
• Start the Configuration Manager when installation is completed. The network is scanned for 
compatible devices automatically.
• When a VideoJet X is listed, click the entry and click the tab Network, located in the right frame.
• Enter the desired IP address (e.g. 192.168.0.40) in the Unit IP address field and click the but-
ton Set at the bottom on the right. The new IP address is valid after a reboot of the unit.