Double-Wall Connector
Information on assembling and installing double-wall 
connectors is provided by the manufacturer of the 
double-wall pipe.  Follow the manufacturer’s installation 
instructions exactly.  Most manufacturers of prefabri-
cated double-wall insulated chimneys also offer double-
wall connector pipes.  Using a chimney and connector 
pipe from the same manufacturer helps simplify the 
assembly and installation.
NOTE:  For installations using double-wall connec-
tors, minimum clearances must conform to listed 
clearances in the Stove and Chimney Connector 
Clearance Charts on page 12 and 13 of this manual.
Assembling Single-Wall 
Chimney Connector
SAFETY NOTE: Always wear gloves and safety 
goggles when drilling, cutting or joining sections of 
chimney connector. 
 
For double-wall connectors, follow the manufacturer’s 
instructions exactly. For single-wall connectors, follow 
the instructions below. 
1. Insert the  crimped end of the first section  into the 
stove’s flue collar, and keep each crimped end pointing 
toward the stove (Fig.5).  Using the holes in the flue col-
lar as guides, drill 1/8” (3 mm) holes in the bottom of the 
first section of chimney connector and secure it to the 
flue collar with three #10 x 1/2” sheet metal screws.
ST242
Chimney connector
12/13/99   djt
Toward 
Stove
Flue Gas 
Direction
ST242
Fig. 5  Crimped sections always point toward the stove so 
that any liquid condensation will not leak out.
2.  Secure each joint between sections of chimney con-
nector, including telescoping joints, with at least three 
sheet metal screws.  
3.  Secure the chimney connector to the chimney.  In-
structions for various installations follow below.
4.  Confirm that the installed stove and chimney con-
nector are correct distances from nearby combustible 
material. See the clearance charts on pages 12 and 13.
NOTE: Special slip pipes and thimble sleeves that form 
telescoping joints between sections of chimney con-
nector are available to simplify installations. They can 
eliminate the need to cut individual connector sections.  
Consult your local dealer about these special pieces.
Securing the Connector 
to a Prefabricated Chimney
Follow the installation instructions of the chimney 
manufacturer exactly as you install the chimney.  The 
manufacturer of the chimney will supply the acces-
sories to support the chimney, either from the roof of 
the house, at the ceiling of the room where the stove is 
installed, or from an exterior wall.
Special adaptors are available from your local dealer 
to make the connection between the prefabricated 
chimney and the chimney connector. (Fig. 6)  The top 
of such adaptors attach directly to the chimney or to the 
chimney’s ceiling support package, while the bottom of 
the adaptor is screwed to the chimney connector.
These adaptors are designed so the top end will fit 
outside the inner wall of the chimney, and the bottom 
end will fit inside the first section of chimney connector.  
Any soot or creosote falling from the inner walls of the 
chimney will stay inside the chimney connector.  
ST419
Joining the chomney
6/27/00   djt
Prefab (Insulated) 
Chimney
Ceiling Support 
Package
Prefab Chimney 
Adapter
Chimney Connector 
(Stovepipe)
ST419
Fig. 6  Joining the chimney connector to a prefabricated 