Set server parameter values 
Note: This request require administrator access 
Method: GET/POST 
 
Syntax: 
http://<servername>/cgi-bin/admin/setparam.cgi? 
[nosync=<value>&]<parameter>=<value> 
[&<parameter>=<value>…][&return=<return page>] 
 
parameter value 
description 
<group>[_<subgroup>]
_<name>.  
value to assigned 
Assign 
<value> 
to the parameter 
<group>_<name>. 
return 
<return page> 
Redirect to the page <return page> after the 
parameter is assigned. The <return page> 
can be a full URL  path or relative path 
according the the current path. If you omit 
this parameter, it will redirect to an empty 
page. 
 
(note: The return page can be a general HTML 
file(.htm, .html) or a Vivotek server script 
executable (.vspx) file. It can not be a CGI 
command. It can not have any extra 
parameters. This parameter must be put at 
end of parameter list) 
 
Return: 
HTTP/1.0 200 OK\r\n 
Content-Type: text/html\r\n 
Context-Length: <length>\r\n 
\r\n 
<parameter pair>