Siemens HICOM 300 ユーザーズマニュアル

ページ / 56
16
Putting into service
Charging the batteries
Batteries supplied are not charged.
Note:
l
New batteries should be initially charged for a minimum period of 16
hours without interruption – irrespective of any messages on the
display.
l
In order to maintain max. battery storage capacity for as long as
possible, the mobile unit should only ever be inserted in the charging
shell when the batteries are empty.
l
The batteries warm up during charging.
l
You can also use the charging shells or base stations of a Gigaset 900/
1000 for charging the mobile unit.
l
Only the following spare batteries are permitted:
Panasonic P-60 AA, Philips R6 NC-P, Saft RC6, UCAR RC6, DAIMON
ACCU 1000, Varta 751RS, Sanyo N-3UN and N-3UC.
l
Insert the mobile unit in the Gigaset 1000L charging shell to charge the
batteries. The mobile unit can be inserted with the display facing
upwards or downwards.
The left LED   
 
B
on the charging shell lights up while the batteries
are charging.
Charging times:
Batteries in the mobile unit: 4 - 5 hours
Replacement batteries in the reserve compartment of the
charging shell: 20 - 24 hours
Battery life:
These times are only achieved after several charging and discharging
cycles.
36 hours in stand-by mode
4 hours when phone is in use.