Gecko Frames Instruction Manual
31
Rear Connectors
 
Frame Alarm Conditions
The conditions monitored by Frame Alarm reporting are:
Frame Health 
Power supply 1 voltage
Power supply 2 voltage
Fan rotation
Frame temperature
Module Health Bus (8900 Video Frames only)
Power supply voltage
Signal present at input
EQ warning
The Module Health bus provides a means for older (legacy) or less capable 
modules (such as DAs with no microprocessor) that cannot communicate 
over the Frame serial bus to report alarm conditions to the Frame Monitor 
or 8900NET module. The reporting is done using a voltage level sent by the 
module to the Frame Alarm connector. When a problem exists on the 
module, the Module Health bus will indicate that a problem exists on the 
module but will not indicate what the problem is. 
Alarm conditions are enabled or disabled by using the Alarm Reporting 
DIP switch(es) on either the Frame Monitor or 8900NET modules. Refer to 
 for the Frame 
Monitor module. For information on setting the 8900NET switches, refer to 
the 8900 Network Interface Module Instruction Manual.
In addition to fault reporting through the Frame Alarm connector, there is 
a red Fault LED on the 8900TF/TFN front cover. This LED is off when no 
fault conditions are detected and on when either an internal fault or a 
signal error is detected.