Klaxon Syrex IS-XN データシート

ページ / 3
 
_______________________________________________________________________________________________________________________________
 
Klaxon Signals Ltd.
   Wrigley Street, Oldham, Lancashire UK OL4 1HW                    sales@klaxonsignals.com            Tel: +44 (0)161 287 5555 
                                                                                                                                        www.klaxonsignals.com               Fax: +44 (0)161 287 5511 
Document No. Klaxon Syrex IS-XN       Issue:  A            11-11-05               Sheet 1 of  3
 
 
 
 
 
 
                 
 
 
 
 
 
 
 
 
1.  INTRODUCTION 
The  Syrex  IS-XN  is  an  ATEX  certified  intrinsically  safe 
beacon  which  will  produce  a  visual  warning  in  a  hazardous 
area.      Red,  Amber,  Green  and  Blue  output  models  are 
available. 
   
 
2. DESCRIPTION 
The  device  will  start  to  flash  when  power  is  applied  to 
terminals + and -. The beacon has two flash rates one double 
flash  per  second  and  two  double  flashes  per  second.  The 
flash  rate  is  selected  by  setting  an  internal  pin  header.  The 
unit is factory set to produce two double flashes per second. 
 
3. SUPPLY VOLTAGE 
The Syrex IS-XN beacon has been designed to operate in a 
hazardous  area  via  a  28V  300  ohm  ATEX  certified  Zener 
barrier  or  galvanic  isolator.  The  beacon  may  be  tested  or 
used  in  safe  areas  without  a  Zener  barrier  or  galvanic 
isolator, but at supply voltages above 16V the internal current 
limit will function  and the brightness may  be reduced.    The 
beacon should not be continuously operated without a barrier 
or isolator with a supply voltage greater than 16V.  
 
 
4. INTRINSIC SAFETY CERTIFICATION 
 
4.1 ATEX certificate 
The  Syrex  IS-XN  beacon  complies  with  the  following 
standards:-  
 
EN50014 : 1997 + A1 and A2 
EN50020 : 2002 
EN50284 : 1999 
 
 
 
The  EC-Type  Examination  Certificate  SIRA  05ATEX2269X 
has  been  issued  by  the  Notified  Body  Sira.  This  confirms 
compliance  with  the  European  ATEX  Directive  94/9/EC  for 
Group  II,  Category  1G  equipment.    The  beacon  carries  the 
Community Mark and subject to local codes of practice, may 
be installed in any of the EEA member countries. 
 
 
 
 
 
 
 
This  instruction  sheet  describes  installations  which  conform 
to  BS  EN  60079:Part14:2003  Electrical  Installation  in 
Hazardous  Areas.    When  designing  systems  for  installation 
outside  the  UK,  the  local  Code  of  Practice  should  be 
consulted. 
 
 
1) The certification marking is as follows:  
WARNING: 
TO AVOID A POSSIBLE ELECTROSTATIC
 
CHARGE ONLY CLEAN WITH A DAMP CLOTH 
Syrex IS-XN Beacon
II 1G   EEx ia IIC T4 (-40ºC <=Ta<= +60°C)
Ui = 28V   Pi = 1.2W
                  Ci = 0   Li = 0
0518
SIRA 05ATEX2269X
Year / Serial No. 05 / 6MB000001
Klaxon Signals Ltd.
Oldham OL4 1HW.  UK.
www.klaxonsignals.com
 
2)  The  equipment  may  be  used  in  zones  0,  1  and  2 
with  flammable  gases  and  vapours  with  apparatus 
groups  IIA,  IIB  &  IIC  and  with  temperature  classes 
T1, T2, T3 and T4. 
3)  The  equipment  is  only  certified  for  use  in  ambient 
temperatures  in  the  range  -40
o
C  to  +60
o
C  and 
should not be used outside this range. 
4)  The  certificate  number  has  an  ‘X’  suffix,  which 
indicates  that  the  certificate  contains  one  of  more 
special  conditions  for  safe  use.  Those  installing  or 
inspecting the equipment should refer to this section 
of the certificate. 
5)  The equipment has not been assessed as a safety-
related  device  (as  referred  to  by  Directive  94/9/EC 
Annex II, clause 1.5). 
6)  Installation of this equipment shall be carried out by 
suitably-trained personnel in accordance with the 
applicable code of practice. 
7)  Repair of this equipment shall only be carried out by 
the manufacturer or in accordance with the 
applicable code of practice. 
8)  The certification of this equipment relies on the 
following materials used in its construction: 
 
 
 
Enclosure:
 
ABS Plastic 
 
 
Lens: 
 
Polycarbonate
 
 
 
 
If the equipment is likely to come into contact with 
aggressive substances, then it is the responsibility of 
the user to take suitable precautions that prevent it 
from being adversely affected, thus ensuring that the 
type of protection is not compromised. 
 
“Aggressive substances” - e.g. acidic liquids or 
gases that may attack metals, or solvents that may 
affect polymeric materials. 
 
“Suitable precautions” - e.g. regular checks as part 
of routine inspections or establishing from the 
material’s data sheet that it is resistant to specific 
chemicals. 
The Syrex IS-XN beacon is CE marked for 
compliance with the European Explosive 
Atmospheres Directive 94/9/EC and the 
European EMC Directive 89/336/EEC 
II 1G EEx ia IIC T4 (-40ºC <= Ta <= +60ºC)